2016 Vital Signs Patient Monitor / NIBP Patient Monitor
2016 Vital Signs Patient Monitor / NIBP Patient Monitor
2016 Vital Signs Patient Monitor / NIBP Patient Monitor

2016 Vital Signs Patient Monitor / NIBP Patient Monitor

Negotiable /Unit

Min.Order:1 Unit

Supply Ability:
300 Unit / Units per Month
Port:
BEIJING SHANGHAI SHENZHEN
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Brand Name:
ANJUE
Model Number:
AJ-3400
Place of Origin:
Anhui, China

Anjue Medical Equipment Co., Ltd.

Business Type: Trading Company
Anqing Anhui China
Main Products: Anaesthesia machine ,Ventilator ,Medical Sterilization Packaging ,Syringe Pump ,Hemotology Analyzer

Product Details

2016 Vital Signs Patient Monitor / NIBP Patient Monitor

2016 Vital Signs Patient Monitor / NIBP Patient Monitor

2016 Vital Signs Patient Monitor / NIBP Patient Monitor

NIBP+SPO2+TEMP+PR (4 ParametersVital Signs Patient Monitor AJ-3400

 

Features

Four parameters: NIBP, SpO2, Pulse Rate, Temperature

* SpO2 waveform, PR strength display

* 2.8 inch color LCD with real time display

* Storage/Review trend data up to 3888 groups, data save time interval settable

* Audio and visual alarm when parameters exceeded and sensor-off

* Built-in rechargeable Li-ion battery, up to 4 hour running time

* Automatic shutdown for power saving, shutdown time interval settable

* Via USB to connect with the computer, unique software for telemonitoring 

  by transmitting data synchronously via internet

* Battery capacity indicatior and prompt when battery low

 

Technical Specifications

*NIBP 

Measure Method: Automatic oscillometric

Patient: Adult and Pediatric

Measurement unite: mmHg/kPa selectable

Measurement mode: Manual, Auto, STAT

Measurement Type: SYS, DIA, MAP

Measurement interval in AUTO mode:1,2,3,5,10,15,20,30,45,60Min

Measuring period in STAT mode: 5 Min

Measure range:

Adult:30~2550 mmHg; child: 30~160 mmHg 

Accuracy: 1 mmHg

Alarm limits range: 

SYS : Upper limits70~250 mmHg,     Lower limits 60~180 mmHg

DIA : Upper limits 40~200 mmHg,     Lower limits35~150 mmHg

MAP : Upper limits 60~230 mmHg,      Lower limits 50~160 mmHg

 

*SpO2 

Measure Range:  35~100%

SpO2 Accuracy:  2%(70~99%), 3%(40~70%)

Pulse Rate Range: 0~254 bpm

Pulse Rate Accuracy: 1 bpm

*Alarm limits range: 

SpO2  upper limits : 95~100%   lower limits: 85~96%

Pulse Rate:keep up with the heart rate

 

*Temperature 

Channel: 1

Input: Body surface thermal-sensitive resistor temperature sensor 

Measurement Unit: °C/°F selectable

Measure range: 0~50℃

Alarm limits range: Upper limits 36~45℃   Lower limits 34~38℃

Measure accuracy: 0.1℃

 

*System Specifications 

Alarm ON/OFF: controlled by general switch and parameter switch (two levels)

Display mode: LED and 2.8’ color LCD screen

Trend data: 3888 groups of SpO2, TEMP,SYS, DIA  trend data, The record time interval can be set to 5 Sec. to 120 Sec. , so that the record time rang can be up to 128 hr.

AC power adaptor      

Input: AC 100~240V, 50/60Hz, 0.7A

Output: DC 5V,2.5A

Internal battery              

Type: 2800mAh/3.7V Li-ion rechargeable battery

Operating Time: 6 hours of stand-by time with a full battery.

Recharge time: 8 hours

Dimension:280mm×190mm×100mm 

Net Weight : 1000g

 

2016 Vital Signs Patient Monitor / NIBP Patient Monitor

Contact Supplier

Mr. Jonathan Dong General Manager Chat Now
Telephone
86-556-5836185
Mobile
13637160963
Fax
86-0556-5836179
Address
Building C3-13, Guangcai Business Garden Anqing,Anhui