Panoramic High Frequency CR X-ray Machine (With Ceph Measurement Function)AJ-CR5
USD $10,000 - $16,000 /Set
Min.Order:1 Set
Anjue Medical Equipment Co., Ltd.
Panoramic High Frequency CR X-ray Machine (With Ceph Measurement Function)
AJ-CR5
Panoramic Parameters
| Panoramic | Ceph |
Focus film distance | 51cm | 158cm |
Time of exposure | 19s | mAs from 2 to 35(12 feet) Normal position |
Functional items | Adult (19 s) Children (16 s) Left side (10 s) Right side (10 s) Middle (10 s ) Mouth open and close TMJ (4*3.2s) Frontal Teeth (12 s) Frontal Sinuses(18 s) | Side face With soft tissued filter |
Cooling and time out | Automatically controlled At most 6 min | Automatically controlled At most 60s |
Film dimensions | 15*30cm flat box | 18*24cm |
X-ray Parameters
Power Supply: 220V,50/60Hz,10A (It can be adjusted as customer’s require.)
Mains Resistance: <1.5ohm at 220 V
X-ray generator: High frequency dc at 20 kHz
Anodic Voltage:60-86 kV, Constant Potential
Anodic Current:4-10 mA, Direct Current
Focus size:0.5*0.5mm
Inherent Filtration:2.5 mm Al
Column Height:230cm
Displacement :90 cm,from 90 to 180 cm
Vertical Movement: Manual Adjustment
Patient Positioning: Manual Carriage Adjustment
Centering Light Lateral
Centering Chin rest
Reference with bite wing
Imaging Parameters of Digital Sensor ipan:
Color Depth | 12bits (4096gray scale) |
Pixel size | 96 micrometer |
Resolution | 4lp/mm |
Scan Time | 10–20sec(depending on host machine) |
Panoramic X-ray Machine AJ-FQK1A
Features
This dental x-ray machine is designed on the principles of x-ray drum curvature tomography.
A small focus x-ray tube is adopted only for dental. It makes the picture clearer.
The unit can radiograph a complete view of curvature of the whole teeth in a picture. The picture includes sinuses, nasal sinus, maxillary, mandibular structure and the whole 32 teeth, temporal, lower jaw joint and its combined relations.
It takes the unit only 16s for a rotational radiography to shoot a panoramic view of whole Dental-Maxilla-Facial region.
An elevating motor is used in the unit, to raise or lower its gantry for radiography the people of different height.
This dental x ray machine can also be used for oral surgery and facial orthopedics.
Main Technical Parameter
X-ray generator | Single focus, half-wave rectification and oil-immersed self-cooled | |
Max rated capability | Current | 10mA |
Voltage | 90kVp | |
Time | 16 sec | |
Power supply | Voltage | 180~240V |
Frequency | 50Hz | |
Power | not lower than 1.8kVA | |
Resistance | not larger than 1Ω | |
Voltage adjustment range of x-ray tube | (divided into 8 steps)55~90kVp | |
Film size | 150mm×300mm | |
Specification of X-ray tube | 0.8mm×0.8mm only for dental | |
Distance between the chin bracket to the floor | 800mm (min)1120 mm (max) | |
Panorama shoot time | 16s | |
Transport dimension, Weight | 100×162×174(cm), (NET)200kg/ (GROSS)320kg |