Electrical current digital ac/dc clamp meter
Negotiable /Piece
Min.Order:1000 Pieces
Fuzhou Yu Xin Electronic Co., Ltd.
1.General Specification
This meter is completely portable. LCD,3 1/2 digits clamp meter with insulation test function (with option 500V insulation tester unit). Designed for use by electricians, technicians, serviceman and hobbyists who required an instrument that is accurate, reliable and always ready for use. It is powered by a standard 9V battery, providing 150-200 operating hours, depending upon the type of battery and usage. It has rugged structure design, good feeling held in operator's hand and convenient use.
DM6266 series clamp meter function table
AC Current: 0.1A to 1000A
Insulation Test: 100K Ω to 2000M Ω (with option 500V insulation tester unit)
AC voltage: 1V to 750V
DC voltage: 1V to 1000V
Resistance: 100m Ω to 20K Ω
Continuity test: 30 ±20 Ω with audio tone
2.Electrical Specifications
The following specifications assume a 1-year calibration cycle and an operating temperature of 18°C to 28°C (64°F to 82°F), at relative humidity up to 80% unless otherwise noted.
AC Voltage (Average sensing, calibrated to rms of sine wave)
Ragnge | Resolution | Accuracy(50Hz-500Hz) |
750V | 1V | ±(1.2% of reading + 5 digits) |
Input impedance: ≥9MΩ
Overload Protection: 750V AC/DC on all ranges
AC Current ( Average sensing, calibrated to rms of sine wave )
Range | Resolution | Accuracy(50Hz-60Hz) |
200A | 100mA | ±(2.5% of reading + 10 digits) |
1000A | 1A | ±(2% of reading + 5 digits) for 800A and below |
The reading is only for Reference for more than 800A |
Jaw Opening: 2.7cm
Insulation test (with option 500V insulation tester unit)
Ragnge | Resolution | Accuracy(50Hz-500Hz) |
20MΩ | 10KΩ | ±(2% of reading + 2 digits) |
2000MΩ | 1MΩ | ±(4% of reading + 2 digits) for 500MΩ and below |
±(5% of reading + 2 digits) for others |
Overload Protection: 250V DC/rms AC on all ranges.
DC Voltage
Ragnge | Resolution | Accuracy(50Hz-500Hz) |
1000V | 1V | ±(1.0% of reading + 2digits) |
Input impedance: 9MΩ
Overload Protection: 1000V DC/peak ACon all ranges
Temperature
Ragnge | Resolution | Accuracy | |
0°C-400°C | 400°C-750°C | ||
0°C-750°C | 1°C | ±1% of rdg ±3d | ±2% of rdg ±1d |
Environment
Normal Operation: 18°C-28°C (64°F to 82°F)
Usable Condition: 0°C-50°C (32°F-122°F)
Storage: -20°C -+60°C (30°F-140°F)
Battery removed and <80% R.H.
Relative Humidity: max. 80%
Function Characteristics
Measurement method: Dual slope integration technical
Reading rate: 3 reading/Sec.
Polarity: Automatic, indicated minus, assumed plus
Overload indication: Blanking of all digits except MSD, decimal point and sign appropriate
Power requirements: 9V battery (NEDA 1604, 6F22)
Battery life: Up to 200 hours typical with Alkaline.
Up to 150 hours typical with Zinc carbon.
Battery indication: Display indicates when approx. 20% of battery life remains.
Display: LCD 3 1/2 digits (1999 count) 0.5" high
Data Hold: All function and ranges with this feature.
Dimension: 9"Lx2.7"Wx1.5"H (230x70x37cm)
Weight: 360g including battery approx.
Accessories
Operator's manual
Test leads
9V battery
Carrying case
Holster