Specifications
ecommunication
2.Transmission of all services over a single network
3.Long-distance transmission with fewer nodes
1/2/5U Devices CWDM/DWDM telecommunication product telecommunication equipment
Product Description
Product Highlights
This section describes key product features.
Transmission of all services over a single network
- The OptiX OSN 1800 encapsulates all services, from low-rate services (such as FE services) to high-bandwidth services (such as 10G services), into OTN frames for transmission.
- The xPON is applied to reduce fiber attenuation in the PON system deployed in urban areas and provide a reliable protection solution within 50 ms.
Long-distance transmission with fewer nodes
- The standard OTN interface supports the forward error correction (FEC) function. After OTN technology is applied to the traditional CWDM system, a transmission distance of up to 120 km (33 dB) is supported, a great improvement compared to the traditional 80 km limit.
- When EDFA is added, the transmission can be further increased to 170 km, long enough for metropolitan transmission.
Lower maintenance expenditure and operation expenditure
- Multi-service, long-distance, and large-capacity transmission helps simplify the network structure.
- The service processing and switching equipment, network management system (NMS), and OSS are all configured at the central node in the system.
- Equipment with simplified transport functions is deployed in unattended equipment rooms in remote areas for wide coverage.
- ITU-T G.709-compliant OTN inband management is supported.
- SDH and WDM/OTN equipment are managed and maintained using the same NMS.
Hybrid networking of CWDM and DWDM
This networking mode enables smooth upgrade from CWDM to DWDM.
Environment-friendly with lower power consumption
- The "All over WDM/OTN" technology helps service equipment be deployed centrally at large sites and directly connected to the client equipment by distance extension technology. The number of end nodes can be decreased by 30% to 90%.
- The OptiX OSN 1800 uses DC/AC power, boasting high adaptability.
- The OptiX OSN 1800 has a box design and is highly integrated, facilitating flexible deployment at any site.
Product Pictures
Specification
Specifications | OptiX OSN 1800 I Chassis | OptiX OSN 1800 II Chassis |
Product appearance |
|
|
Dimensions (mm) | 44 (H) × 442 (W) × 220 (D) | 88 (H) × 442 (W) × 220 (D) |
Number of slots for service boards | 3 | 7 |
Switch | Optical | Implements the add/drop multiplexing of any 2 wavelengths or 4 and 8 adjacent wavelengths in the OTM and the OADM. |
Electrical | - Inter-board cross-connections of Any services at a rate lower than 1.25 Gbit/s and 10GE LAN services are supported.
- Intra-board cross-connections of Any services at a rate lower than 2.5 Gbit/s are supported, and intra-board cross-connections of VC-4 or VC-12 and ODU0/ODU1/ODUflex/ODU2 services are supported.
|
Wavelength | - DWDM: On a network that contains only OptiX OSN 1800, a 16-channel DWDM system is supported. On a hybrid network that contains OptiX OSN 1800 and OptiX OSN 8800, a 40-channel DWDM system is supported if OBU boards are used on the network.
- CWDM: 8-ch(max)
|
Wavelength range | The system splits wavelength into DWDM band and CWDM band. Systems of different types use different bands. - The OptiX OSN 1800 DWDM system adopts the C band in the fiber communication window. The minimum channel spacing of 0.8 nm in C band. The number of available wavelengths is 40. The operating wavelength range is from 192.10 THz to 196.00THz (1560.61 nm to 1529.55 nm).
- The OptiX OSN 1800 CWDM system adopts the channel spacing of 20 nm. The number of available wavelengths is 8. The operating wavelength range is from 1471 nm to 1611 nm.
|
Max. rate per channel | 10 Gbit/s (OTU2) |
Service types supported | SDH service, PDH service, OTN service, Ethernet service, CPRI service, SAN service, SONET service, PON service, Video service and others |
Line rate | 2.5 Gbit/s, 10 Gbit/s |
Pluggable optical/electrical module | - Optical module: SFP, XFP, SFP+, TXFP
- Electrical module: GE SFP, FE SFP
|
Topology | Point to point, Chain, Star, Ring |
Redundancy and Protection | Equipment level protection | Power Redundancy, Fan Redundancy |
Network level protection (OTN) | Client 1+1 Protection, Intra-Board 1+1 Protection, ODUk SNCP, Optical line protection, SW SNCP, LPT |
Network level protection (Ethernet) | ERPS, LAG, LPT(Service-based), MSTP, STP and RSTP, VLAN SNCP |
Maintenance | ETH OAM | - Ethernet service OAM: supports continuity check (CC), loopback (LB), linktrace (LT), and OAM_Ping.
- Ethernet port OAM: supports OAM auto-discovery, link performance monitoring, remote loopback, and self-loop detection.
|
Synchronization | - Synchronous Ethernet clock
- IEEE 1588v2
- SDH clock
- External time source (1PPS+TOD)
|
Standard working voltage | - -48 V/-60 V DC power input
- 100 V to 240 V AC power input
|
Installation mode | - 19-inch cabinet or 19-inch open rack
- ETSI 300mm cabinet
- Wall- or Pole-mount
|
MTTR | 4 hours |
MTBF | 61.44 years |
Item | N63E/N63B Cabinet | 19-Inch Cabinet | 19-Inch Open Rack |
Appearance |
NOTE: N63E cabinets use front columns while N63B cabinets use middle columns. |
|
|
Weight | N63E cabinet: 45 kg (99.2 lb.) N63B cabinet: 60 kg (132.3 lb.) | 76 kg (167.6 lb.) | 2200 mm-high cabinet: 25 kg (55.1 lb.) 2000 mm-high cabinet: 22 kg (48.5 lb.) |
Dimensions (H x W x D) | 2200 mm x 600 mm x 300 mm (86.6 in. x 23.6 in. x 11.8 in.) | 2200 mm x 600 mm x 600 mm (86.6 in. x 23.6 in. x 23.6 in.) | - 2200 mm x 600 mm x 600 mm (86.6 in. x 23.6 in. x 23.6 in.)
- 2000 mm x 600 mm x 600 mm (78.7 in. x 23.6 in. x 23.6 in.)
|
Available space | 45 U | 45 U | 2200 mm (height): 45 U 2000 mm (height): 40 U |
Space required by the hardware | - Ordinary OptiX OSN 1800 I chassis: 1 U
- OptiX OSN 1800 I chassis integrated with an FMT: 2 U
- Ordinary OptiX OSN 1800 II chassis: 2 U
- OptiX OSN 1800 II chassis integrated with an FMT: 3 U
- DC power distribution unit (PDU): 3 U
- FMT: 1 U
- Dispersion compensation module (DCM) frame: 1 U
|
Configuration principles | - Configure one FMT for each OptiX OSN 1800 II chassis and each two OptiX OSN 1800 I chassis.
- Configure a maximum of 12 OptiX OSN 1800 I chassis in one cabinet (ensure that the temperature in the equipment room is within the range from -5°C to +40°C).
- Configure a maximum of eight OptiX OSN 1800 II chassis in one cabinet (ensure that the temperature in the equipment room is within the range from -5°C to +40°C).
- For an N63E cabinet, keep a minimum distance of 37 mm between two adjacent OptiX OSN 1800 II chassis and a minimum distance of 32 mm between two adjacent OptiX OSN 1800 I chassis, to facilitate fiber routing.
- No space needs to be reserved between devices in an N63B cabinet because fibers can be routed through the space between the column and a side panel of the cabinet.
- No space needs to be reserved between chassis and the FMTs configured for the chassis.
- One FMT is configured for each OptiX OSN 1800 II chassis and each two OptiX OSN 1800 I chassis.
- Configure a maximum of 12 OptiX OSN 1800 I chassis in one cabinet (ensure that the temperature in the equipment room is within the range from -5°C to +40°C).
- Configure a maximum of eight OptiX OSN 1800 II chassis in one cabinet (ensure that the temperature in the equipment room is within the range from -5°C to +40°C).
- No space needs to be reserved between devices in a cabinet because fibers can be routed through the space between the column and a side panel of the cabinet.
- No space needs to be reserved between chassis and the FMTs configured for the chassis.
| |
NOTE: 1 U = 44.5 mm The power consumed by an N63E cabinet, an N63B cabinet, a 19–inch cabinet, or a 19–inch open rack must not exceed 1500 W. |
Network Application:
Certifications
Company overview
ChuCheng Information Technology Co., Ltd. , which provides main services in terms of broadband communications and information technology industries, is a research and development, production, sales, service integration, high-tech enterprises. Our products mainly cover the optical signal transmission and access, signal transmission and access, photoelectric signal conversion and photoelectric signal and so on.
We are now the agent of well-known international brands such as HUAWEI, ZTE, CISCO, ZYXEL,
Grandstream, etc. Our customer include major national telecom carriers, as well as radio and television, electricity, mining and other industry professional network users; We have already established a long-term friendly and cooperative relations with them. In addition, the company has been actively expanding into foreign markets. The products are exported to Europe, America, Southeast Asia, the Middle East as well as Japan, Korea and other neighboring countries.
We will constantly improve our service and quality to create a win-win situation.
Please contact us to know details.
ShangHai ChuCheng Information and Technology CO.,LTD
Address: Room 110,No.389 JinWan Road, ShangHai , China
Tel:0086-21-58718070 ext 8030
Fax: 0086-21-58714662-8888
Attn: Camille gu
Skype:melody.li221
Trade Information:
Trade terms: FOB,CIF,CFR,etc
Price Terms: L/C,D/P,T/T,Western Union,PAYPAL
Payment Terms: T/T in advance
MOQ: 1 pcs
FOB Price:US $1 - 1,000 / Piece
Port: Shanghai
Lead time: Within 5 working days after receipt payment.
Shipment: Express, Air, Sea
Supply capability: 200 Piece/Pieces per Week
Sample availability: Yes( not free)
- Package information: carton package with Huawei original package
After-Sales Service
We can provide detail documents and remote help for device installation and configuration.
Warranty: 1 year. ( After the quality guarantee period began to charge appropriate maintenance service fee.)
Our company promises goods enjoy full return due to quality problem since goods delivered within 7 days or 15 days , returned goods must keep original state and it’s accessories are complete.