popular evacuated tube solar thermal collector with heat pipe for water heating
USD $200 - $500 /Set
Min.Order:1 Set
Haining Green Import&Export Co., Ltd.
Evacuated tube solar collector, heat pipe solar collector
Feature:
1. there is no water in the vacuum tube, the system can work as usual if one tube is broken.
2. operation pressure is 0.7 Mpa, and the test pressure is 1.0 Mpa.
3. it is used with existed tank in the basement.
4. the frame can be installed on the flat roof or inclined roof.
Solar thermal collector Material Details | |
Solar thermal collector Model | XKPC-58-1800 |
Flow type | Heat pipe |
Heat pipe material | TU1 copper |
Heat pipe size | Top: Ø14* 1mm or Ø24* 1mm; Body: Ø8* 0.7mm |
Tube diameter | φ58/1800mm |
Solar vaccum glass tube | High borosilicate |
Coating of absorber on glass tube | Cu/SS-ALN(H)/SS-ALN(L)/ALN |
fins around heat pipe | single long Aluminum(1.6m) |
Manifold pipe material | TU2 copper (Ø35x0.8mm for 14mm heat pipe or Ø38x0.8mm for 24mm heat pipe |
Manifold casing material | 6063 Aluminum alloy frame(1.8mm) |
Insulation material in manifold casing | Rook wool or PU |
Thickness of insulation(mm) | 45 |
Density of insulation (kg/m3) | 93 |
Frame material | 6063 Aluminum alloy frame(2mm) |
Frame and manifold casing finish | Black Powder coated or Argentine |
Sealing Materials | EPDM |
Model | Aperture area(M2) | vacuum tube | packing volume(m³) | Gross wet(KGS) | container loading(set) | ||||
dia(mm) | length(mm) | qty(pcs) | 20GP | 40GP | 40HQ | ||||
XKPC58-1800-15 | 1.421 | 58 | 1800 | 15 | 0.23 | 48.1 | 117 | 247 | 291 |
XKPC58-1800-20 | 1.894 | 58 | 1800 | 20 | 0.33 | 64.1 | 81 | 172 | 203 |
XKPC58-1800-25 | 2.369 | 58 | 1800 | 25 | 0.38 | 79.5 | 71 | 150 | 176 |
XKPC58-1800-30 | 2.842 | 58 | 1800 | 30 | 0.42 | 96.2 | 64 | 135 | 159 |
Technical data of SRCC solar collector | ||||
Solar thermal collector Model | XKPC-58-1800 | |||
Numbers of tube(pcs) | 30 | 25 | 20 | 15 |
Absorber area approx.(m2) | 2.493 | 2.0325 | 1.626 | 1.2195 |
Gross size(m) | 2.05×1.45×2.1 | 2.05×1.45×1.945 | 2.05×1.45×1.57 | 2.05×1.45×1.19 |
Weight Empty(kg) | 93 | 80 | 63 | 48 |
Hydraulic Connections | G3/4" male thread/22mm | |||
Packages each unit (tubes/manifold casing/frame in cartons) | 3ctns/1ctn/1ctn | 2ctns/1ctn/1ctn | 2ctns/1ctn/1ctn | 1ctns/1ctn/1ctn |
Loading qty in 20 GP/40GP/40HQ | 63/130/145 | 82/170/200 | 90/185/210 | 133/276/325 |
Fluid volume(L) | 1.7 | 1.5 | 1.2 | 0.9 |
Min. volume flowrate per collector(L/H) | 108 | 90 | 72 | 54 |
Rated volume flowrate per coll.(L/H) | 180 | 150 | 120 | 90 |
Max. volume flowrate per collector(L/H) | 1200 | 1200 | 1200 | 1200 |
Maximum operation pressure(Bar) | 6 | |||
Test pressure(Bar) | 12 | |||
Heat transfer fluid | Anti-freeze Fluid (Water-Glycol) | |||
ing temp.(°C) | 229 | |||
Hot water(L/Day) | 240 | 200 | 160 | 120 |
ΔT | 35°C(Radiation>=800w/m2.day) | |||
Collector efficiency | 76.40% | 76.20% | ||
Medium | Pure water | |||
Start-up Temperature of heat pipe | ≤30°C | |||
Warranty | 5 years |