Krohne VA40/ VA45 Variable area flowmeter
1. VA40 VA45 Variable-area flowmeter
The VA40 flowmeter is suitable for measuring the flow rate of liquids or gases.
The VA45 flowmeter is suitable for measuring gases at low operating pressures
Highlights
• Consistently used overall length concept
• Low loss of pressure for gas applications
• Low maintenance
• Optional limit switches
• Simple installation and start-up
• Simple float guidance
• Shatter protection
Industries
Can be used in all industrial sectors, for example:
• Chemical
• Food and beverages
• Heating, cooling, and air conditioning
• Iron, steel and metal
• Mining and building materials
• Oil and gas
• Pharmaceutical
• Power plants
• Mechanical engineering
• Pulp and paper
• Water
• Furnace construction
Applications
• Measuring gas
• Burner controlling
• Water circuits
2. Technical data
• The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
• Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
2.1 Measuring system
2.2 Operating conditions
2.3 Materials
2.4 Limit switches
(only VA40)
2.5 Use of the limit switch
3.0 Dimensions and weights
Dimensions VA40
3.1 Dimensions VA45
3.2 Measuring ranges
Measuring ranges VA40
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request.Conversion of other media or operating data
(pressure, temperature, density, viscosity) isperformed using the calculation method in
accordance with VDI /VDE Directive 3513.
Measuring ranges VA45
The operating pressure should be at least 5 times the pressure loss for gases! The specified
pressure drops are valid for water and air at maximum flow rate. Other flowranges on request.
Conversion of other media or operating data (pressure, temperature, density, viscosity) is
performed using the calculation method in accordance with VDI /VDE Directive 3513.
3.3 Installation condtitions
When installing the device in the piping, the following pointsmust be observed:
• The variable area flowmeter must be installed vertically (measuring principle). Flow direction
from bottom to top. For installation recommendations please refer also to VDI/VDE 3513
Sheet 3.
• Before connecting, blow or flush out the pipes leading to the device.
• Pipes for gas flow need to be dried before the device is installed.
• Use connectors suitable for the particular device version.
• Align the pipes centrically with the connection bores on the measuring device so they are free
of stresses.
• If necessary, support the pipeline to reduce vibrations being transmitted to the measuring
device.
• Do not lay signal cables directly next to cables for the power supply.