316L IFM SM2000 liquid flow sensor G12 flow sensor
USD $500.00 - $500.00 /Piece
Min.Order:1 Piece
Xian XK Sensor Equipment Co., Ltd.
316L IFM SM2000 liquid flow sensor G12 flow sensor
In-line flow meter monitors small dosing quantities in water and aqueous solutions up to 200 ml/min; magmeter monitors conductive media upto 26 gpm; and ultrasonic flow meter monitors water applications up to 50 gpm
Technical Data:
Product characteristics | |||
Magnetic-inductive flow meter | |||
Quick disconnect | |||
Process connection: G2 flat seal | |||
connection to pipe by means of an adapter | |||
Function programmable | |||
Totalizer function | |||
Empty pipe detection | |||
2 outputs OUT1 = flow monitoring (binary), flow rate meter (pulse), preset meter (binary) OUT2 = flow monitoring or temperature monitoring (analog or binary) | |||
Input for counter reset | |||
4-digit alphanumeric display | |||
Measuring range | |||
5...600 l/min | |||
Application | |||
Application | conductive liquids of the fluid group 2 according to the Pressure Equipment Directive (PED) (conductivity: ≥ 20 µS/cm / viscosity: < 70 mm²/s at 40°C) | ||
Pressure rating [bar] | 16 | ||
Medium temperature [°C] | -10...70 | ||
Electrical data | |||
Electrical design | DC PNP/NPN | ||
Operating voltage [V] | 18...32 DC ¹) | ||
Current consumption [mA] | < 150 | ||
Insulation resistance | > 100 (500 V DC) | ||
Protection class | III | ||
Reverse polarity protection | yes | ||
Outputs | |||
Output function | OUT1: normally open / normally closed programmable or pulse or frequency or empty pipe detection or IO-Link OUT2: normally open / normally closed programmable or analogue (4...20 mA; 0...10 V, scalable) or empty pipe detection | ||
Current rating [mA] | 2 x 250 | ||
Voltage drop [V] | < 2 | ||
Short-circuit protection | yes (non-latching) | ||
Overload protection | yes | ||
Analog output | 4...20 mA; 0...10 V | ||
Max. load | 500 (4...20 mA) | ||
Min. load | 2000 (0...10 V) | ||
Pulse output | flow rate meter | ||
Frequency range [Hz] | 0.1...10000 | ||
Measuring / setting range | |||
Empty pipe detection | normally closed / open | ||
Flow monitoring | |||
Measuring range | 5...600 l/min | 0.3...36 m³/h | |
Display range | -720...720 l/min | -43.2...43.2 m³/h | |
Resolution | 0.5 l/min | 0.02 m³/h | |
Set point, SP | 8...600 l/min | 0.5...36 m³/h | |
Reset point, rP | 5...597 l/min | 0.3...35.8 m³/h | |
Analog start point, ASP | 0...480 l/min | 0...28.8 m³/h | |
Analog end point, AEP | 120...600 l/min | 7.2...36 m³/h | |
Flow end point, FEP | 20...600 l/min; 1.2...36 m³/h | ||
Low flow cut-off, LFC | 5...15 l/min | 0.3…0.9 m³/h | |
in steps of | 0.5 l/min | 0.02 m³/h | |
Frequency end point, FrEP | 0.01...10 kHz | ||
in steps of | 10 Hz | ||
Measuring dynamics | 1:120 | ||
Volumetric flow quantity monitoring | |||
Measuring range [l...m³] | 0.0…9999 x 10³ | ||
Display range [l...m³] | 0.0…9999 x 10³ | ||
Set point, SP [l...m³] | 0.0…9999 x 10³ | ||
Pulse value | 0.1 l...600 x 10³ m³ | ||
in steps of | 0.1 l | ||
Pulse length [s] | 0.008...2 | ||
Temperature monitoring | |||
Measuring range [°C] | -20...80 | ||
Display range [°C] | -40...100 | ||
Resolution [°C] | 0.2 | ||
Set point, SP [°C] | -19.2...80.0 | ||
Reset point, rP [°C] | -19.6...79.6 | ||
Analog start point, ASP [°C] | -20...60 | ||
Analog end point, AEP [°C] | 0...80 | ||
in steps of [°C] | 0.2 | ||
Accuracy / deviations | |||
Flow monitoring | |||
Accuracy | ± (0.8% MW + 0.5% MEW) ²) | ||
Repeatability | ± 0.2% MEW |
About us:
Xi'an XK Sensor Equipment Co,Ltd is located in Xi'an city, which is China's instrument authoritative research and development center, mainly engaged in four categories products:
Press Transmitter Branch: Rosemount, Yokogawa, ABB, SIEMENS, E+H, Honeywell.
Temperature Transmitter Branch: Rosemount, Yokogawa, Honeywell, E+H, ABB
Flow meter Branch: Rosemount, Yokogawa, Honeywell, E+H, ABB, Yamatake, HROHNE
Valve Positioner Branch: YTC, FISHER, SIEMENS, YAMATAKE, ABB, KOSO, YTC
We look forward to establishing long-term business relationship with you!