Electric cheap portable External concrete vibrator price
Negotiable /Set
Min.Order:100 Sets
Henan Dasion Machinery Co., Ltd.
ZNF50 china manufacturer Pneumatice Motor external compactor concrete vibrator
high efficiency and good feedback concrete batching mixing plants for sale
Hot selling portable concrete batching plants with PLC control
Hot-sale Low Cost YHZS Series Concrete Batching Plant in sri lanka with good feedback
Hot-selling mobile concrete batching mixing plant machine in Uruguay
Application range of external portable concrete vibrator : |
This series of concrete vibrator are widely used construction, transportation, port, mining and metallurgy, plastic, semi-rigid, dry and hard vibration construction. Such as concrete plates, pavement, floor and roof of the building structure.
The vibrator is an important tool for concrete construction; it also can be used as vibration source of all kinds of vibration table and vibration equipments. Such as casting, screening, loading, feeding and other mechanical equipment.
Type ZJY20 vibrator is designed against extrusion molding press, which makes the pre-stressed hollow floor slabs. It can continuously operate for a long time.
Structure Feature of external concrete vibrator : |
1. This series of concrete vibrator is safe, reliable, stable performance, simple structure, easy maintenance.
2. Concrete vibrator adopts special-designed vibration motor.
3. Concrete vibrator adopts full-enclosed structure, anti-dust anti-moisture.
4. Unique eccentric structure, symmetrically distribute at outer shaft. Such as ZW10, ZF150, ZF220, ZW20 model, the vibrating force can be adjusted according to construction situation,
Working Principle of external portable concrete vibrator : |
The working principle of external concrete vibrator as following:
Install one or two eccentric block(s) at each end of vibration motor shafts, when electric motor rotates, the eccentric block will rotates around central shaft, then generating centrifugal force, thus forming a vibration.
Technical Feature of external concrete vibrator : |
Type | Unit | ZW5 | ZW10 | ZF220 | ZW20 | ZJY20 | ZW5A | ZW10B | ZF1 | ZF150A |
Motor power | Kw | 0.8 | 1.1 | 2.2 | 3 | 2 | 0.8 | 1.1 | 0.12 | 1.5 |
Voltage | V | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 |
Supply freq. | HZ | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Vibration freq. | HZ | 48 | 48 | 48 | 48 | 48 | 48 | 48 | 47 | 48 |
Exciting force | N | 4200 | 9200 | 11000 | 15000 | 14000 | 3000 | 6700 | 500 | 9200 |
No-load amplitude | mm | 1.5 | 2.3 | 2.0 | 1.8 | 1.9 | 1.5 | 2.3 | 0.6 | 2.0 |
Phase | Ph. | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Electric current | A | 1.74 | 2.45 | 4.6 | 4 | 4 | 1.74 | 2.45 | 0.372 | 3.3 |
Weight | Kg | 35 | 44 | 55 | 90 | 83 | 35 | 44 | 9 | 52 |
Maintenance of concrete vibrator : |
1. When moving and operating concrete vibrator, handle gently, avoid damage.
2. Keep external machine clean in order to avoid preventing electric motor radiating.
3. Cut off power immediately, check machine, when find abnormal sound or abnormal vibration and burnt smell during concrete vibrator rotates.
4. Rolling bearing lubricating grease adopt 3# complex grease, regular cleaning, replace rolling bearing lubricating grease, when concrete vibrator work 150-200 hours , don’t paint too much, it is advisable to fill one third of bearing cavity in order to avoid bearing fever.
5. Check bearings, seals, quick-wear parts’ wear condition regularly. Find problem, replace it.
Malfunction and Elimination of concrete vibrator: |
NO. | Malfunction | Malfunction Cause | Elimination Method |
1 | Concrete vibrator does not vibrate | 1.Power is clogged 2. Rotor shaft is stuck | 1.Change power cable and fuse 2.Adjust Axial gap |
2 | Vibrator temperature rises | 1. Improper model 2. Too much or less bearing grease 3. Bearing wear and tear 4. Foot bolt loose | 1. Choose the appropriate vibrator 2. Increase or decrease grease 3.Change bearing 4. Tighten the connecting bolt |
3 | vibrator rotation or deviation | Two eccentric blocks are not in the same stalls | Adjust the two eccentric blocks to the same stalls |
4 | Abnormal vibration sound | 1. Cut off the power 2. Sundries in concrete vibrator 3. Bearing lack grease 4. Bearing is broken | 1.Chagne the power line 2.Clear sundries 3.Add grease 4.Change bearing |