YSTE180V medical laboratory full auto analyzer biochemistry veterinary
Negotiable /Unit
Min.Order:1 Unit
Guangzhou Yueshen Medical Equipment Co., Ltd.
YSTE168V hot sale semi-auto veterinary clinic animal blood chemistry analyzer
YSTE880V good selling top quality 35 tests per hour hematology animal blood analyzer
popular type veterinary hospital medical fully auto vet analyzer hematology
RS232 interface PC connecting best price vet fully auto hematology analyzer
stable quality laboratory pet clinic cheapest vet chemistry analyzer price
lowest price stable performance 35 samples per hour fully auto hematology equipment vet
medical laboratory full auto analyzer biochemistry veterinary
Model:YSTE180V
biochemistry analyzer,
YSTE180V Automatic Chemistry Analyzer | Specifications | ||||||||
Analyze System | |||||||||
Throughput | Maximun 300T/h,Constant 180T/h(non-ISE) | ||||||||
Theory | Absorption spectronmetry,Transmission turbidimetry | ||||||||
Methodology | End-point,Fixed-time,Kinetic,Monochromatic/bichromatic | ||||||||
Test according set up,random access | |||||||||
Reaction plate | Contain 81 reaction cuvettes | ||||||||
Miximun reaction time: 15 minutes | Minimum reaction volume: 150 ul | ||||||||
Material of cuvettes | Special UV-transparent optical glass | ||||||||
Can to be chose one-off cuvettes or automatically cuvettes washing | |||||||||
Optical System | |||||||||
Light Source | Halogen-tungsten lamp | ||||||||
Photometer | Reversed optics | ||||||||
Wavelength | 340nm-900nm wavelength option | ||||||||
Absorption | 0-4 Abs | ||||||||
Reagent/Sample Handling | |||||||||
Sample volume | 2-100 ul,step by 0.1 ul | ||||||||
Sample plate | Contain 60 sample positions | ||||||||
Reagent/Sample Probe | Automatically checked,patent technology liquid level detection,collision protection probe cleaning:Automatic washing for both inside and outside | ||||||||
Samples cup | Support one-off blood cuvettes,micro cups,plastic cuvettes | ||||||||
Reagent volume | 20-500 ul,step by 0.1 ul | ||||||||
Reagent plate | Contain 60 reagent positions | ||||||||
Sample/reagent probe | Collision protection liquid level detection;Internal and external probe washing;Probe depth adjustment automatically | ||||||||
Reagent bottle | 15ml & 30ml; Dead volume less than 0.5 ml | ||||||||
Temperature Control | |||||||||
Maintenace free heater elements | Temperature maintainance within 3 minutes | Temperature fluctuation: ±0.1°C | |||||||
Reaction temperature: 37±0.1°C | Temperature of reagent compartment : 2-10°C | ||||||||
Operation system | |||||||||
Software :WindowsXP,2000 | Database: SQL Server | ||||||||
Data Storage | Automatic store & copy;No time and volumn limit;Lifetime preservation | ||||||||
Print format | Can be set up,offer several standard format | ||||||||
Calibration mode | Linear curce type:Single-point linear,two-point linear and multi-point linear none linear;Curve type:Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | ||||||||
QC Methods:Real time,within day & between day | Quality Control Diagram: L-J,cumulative,twin plot | ||||||||
Control software | Random set up,default westgard multi-rule | ||||||||
Status display | Real time monitoring of reagent residual volume. Running status of reagent tray,samples tray | ||||||||
Adjustment | Dynamic and real time display of running status;Intelligent carry over settings to adjust test sequence;Original reaction data record;Detail profile of alert messages | ||||||||
Setting | Operation permission setting,Item setting,cross polution setting,cuvette blank setting | ||||||||
Others | |||||||||
Water consumption:Less than 2 L per hour | Power Supply: AC 220V±22V 50Hz±1Hz | ||||||||
Frequency:Maximun 600VA | Dimension:782mm×581mm×545mm | ||||||||
Weight:60kg | Accessory: Software |
biochemistry analyzer
biochemistry analyzer
veterinary automatic chemistry analyzer
veterinary automatic chemistry analyzer
medical laboratory full auto analyzer biochemistry veterinary