(YJV)Electric Cable 3 * 240mm2+1*120mm2 With PVC Sheath
USD $1 - $20 /Meter
Min.Order:1000 Meters
(YJV)Electric Cable 3 * 240mm2+1*120mm2 With PVC Sheath
Descrption :
1. 0.6/1KV YJV electric cable/power cable
2.GB and IEC standard.
3.ISO,CCC certification .
4. Direct factory.
Application :
It is used to transmit and distribute power in power transmission and distribution system of 0.6/1KV,apply to lay indoor,in tunnel,cable trench.
Type & Designation:
Type | Name | Application | |
Copper conductor(CU) | Aluminum Conductor(Al) | ||
YJV YJY | YJLV YJLV | XLPE insulated, PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force during laid. |
YJV22 YJV23 | YJLV22 YJLY33 | XLPE insulated, steel tape armoured, PVC or PE sheathed power cable | For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV32 YJV33 | YJLV32 YJLV33 | XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable | For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
YJV42 YJV43 | YJLV42 YJLV43 | XLPE insulated, thick steel armoured, PVC or PE sheathed power cable | Can be laid in water or soil eith drop height .Able to bear positive pressure and pulling force. |
Type | Name | Usage |
VV | PVC insulated PVC sheathed power cable | Can be laid at indoor, tunnel and tube .Cable cannot under take mechanism outside force |
VLV | ||
VY | PVC insulated and PE sheathed power cable | Can be laid at indoor, tunnel tube and serious polluted places. Cable cannot undertake mechanism outside force |
VLY | ||
VV22 | PVC insulated steel belt armored and PVC sheathed power cable | Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force |
VLV22 | ||
VV23 | PVC insulated steel belt armored and PE sheathed power cable | Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV23 | ||
VV32 | PVC insulated fine steel wire armored PVC sheathed power cable | Can be laid at indoor, underground and mining well .Cable can undertake mechanism outside force |
VLV32 | ||
VV33 | PVC insulated fine steel wire armored PE sheathed power cable | Can be laid at indoor, underground .Cable can under take mechanism outside force |
VLV33 | ||
VV42 | PVC insulated thick steel wire armored PE sheathed power cable | Can be laid at indoor, underground,mining well .Cable can under take mechanism outside force |
VJV42 | ||
VV43 | PVC insulated fine steel wire armored PVC sheathed power cable | Can be laid at indoor, underground ,mining well and the places of be terrible polluted. Cable can undertake mechanism outside force |
VLV43 |
Using Character:
1.Max. permissible continuous operating temperature of conductor ≤70°
2 .Max. short circuit temperature of cable conductor shall not exceed 160°C(5s maximum duration)
3. The ambient temperature when installation should be above 0°C.
4.The product is manufactured according to the standard of GB,IEC,DIN and ICEA upon request