HIOKI IR4056-20 digital megger (HiTESTER 3454-11)
USD $416.67 - $416.67 /Set
Min.Order:1 Set
Qingdao Zhibohongyu Trading Co., Ltd.
IR4056-20 andIR4057-20Features insulation resistance meter
IR4057-20 measurement results can be displayed in the form of a histogram , making it easier to judge. In addition , IR4057-20 high performance comparator function faster than IR4056-20 judgment (IR4057-20 about 0.3s, IR4056-20 about 0.8s).
IR4056-20 insulation resistance meter resistance measurement
Standard test line L9787 | IR4056-20, IR4057-20 | ||||
Rated measuring voltage (DC) | 50 V | 125 V | 250 V | 500 V | 1,000 V |
Effective maximum display value | 100 M | 250 M | 500 M | 2,000 M | 4,000 M |
Central display value | 2 M | 5 M | 10 M | 50 M | 100 M |
The first effective measuring range [M] | 0.200 to 10.00 | 0.200 to 25.0 | 0.200 to 50.0 | 0.200 to 500 | 0.200 to 1,000 |
Accuracy | 4% rdg. | ||||
2nd effective measuring range [M] | 10.1 to 100.0 | 25.1 to 250 | 50.1 to 500 | 501 to 2,000 | 1,010 to 4,000 |
Accuracy | 8% rdg. | ||||
Other measuring ranges [M] | 0 to 0.199 | ||||
Accuracy | 2% rdg. 6 dgt. | ||||
Maintain nominal voltage Lower limit of the measuring resistance values | 0.05 M | 0.125 M | 0.25 M | 0.5 M | 1 M |
Externally applied voltage protection | 600 V AC10 seconds | 1,200 V AC10 seconds |
IR4056-20 insulation resistance meter basic parameters (Red part: Only IR4057-20)
Show | B LCD , backlit ,The graph shows (IR4057-20 only ) |
Response time | Measurements IR4051: 1.0/IR4052:0.6 seconds |
Function | Live wire warning , automatic discharge , grounding conduction confirmation , AC / DC automatic recognition, recognition by computer , check the fuse break , the remaining battery display |
IR4057 additional features | A score display , the display is switched insulation measurement ( median / chart with or without ) |
Power supply | 5 battery * 4 |
Continuous use of time | About 20 hours ( comparator & backlight OFF, 500V range measurement port open when ) |
Over- range protection | Approximately 10 minutes ( subject to final operation ) |
Use of temperature and humidity range | 0 C to 40 C, 90% or less ( non-condensing ) |
Save temperature and humidity range | -10 C to 50 C, 90% or less ( non-condensing ) |
Maximum rated voltage to earth | AC / DC 600V ( measurement category ) expects over-voltage 6000V |
Pressure | AC 7060V 50 / 60Hz measured between the port and the housing 1 minute |
IP protection class | IP40 |
Use standard | EN61326 (EMC), EN61557-1 / -2 / -4 * / - 10 |
Fall Protection | Cement floor less than 1m |
Volume | IR4056-20: 159W * 177H * 53D (mm) IR4057-20: 152W * 92H * 40D (mm) |
Weight | IR4056-20: 600g IR4057-20: 440g ( with battery , without test line ) |
Accessories | Manual, the 5th alkaline batteries × 4, test line L9787, suspenders |
Option | Test line with a remote switch ( red ) L9788-10, with remote switch test line suits L9788-11, the front end of the probe L9788-90, breaker probe L9787-91, breaker probe L9788-92, magnetic converter 9804- 02 |