Patient monitor handheld for dog
Negotiable /Set
Min.Order:1 Set
Patient monitor handheld for dog
[Features]
1.Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data;
2.Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power;
3.Adjustable audible and visual alarms, and sensor off alarm;
4.Long time monitoring and sleeping monitoring;
5.Easy to carry, suitable for ambulance center, has the stand for fixing;
[Prior]
1.Storage and review data up to 3888groups via Trend Graph and Trend List.
2.USB and Bluetooth data upload;
3.Horizontal and vertical display selectable;
4.Big font screen interface is easy to observe;
5.Back light can be adjusted;
6.Free advanced software
7.Optional Bluetooth printer to print the waveform and data out.
[Technical Specification]
[ General Specifications]
Size: | 209mm×104mm×47.5mm | Net Weight: | 655g |
Measurement Display: | |||
Measurement Display: | color TFT- LCD/touch screen | Power Supply Indicato: | Dual-color LED (red/green) |
Charging indicator: | A green LED |
[Power Supply]
AC Power Adaptor | |||
Input: | 100~240VAC, 50/60Hz, 0.7A | Output: | DC 5V, 1.5A |
Battery | |||
Li-ion rechargeable battery, 3.7V/7200mAH | |||
Operating Time: | 15hours with full battery capacity(Condition: 25℃, NIBP working period is 15 minutes) | Recharge Time: | 10 hours. |
[Environment]
Temperature | |||
Working: | 0 C~45 C | Transport and Storage: | -25 C~85 C |
Humidity | |||
Working: | 30% ~85 % | Transport and Storage: | 30% ~95 % (no condensation) |
[Monitoring Parameter]
ECG | |||
Input: | 3- lead ECG cable, standard AAMI cable connector | Lead Selection: | I,II,III |
Gain Selection: | ×1,×2,×4,×8 | Sweep Speed: | 12.5, 25, and 50 mm/s |
Frequency Response: | None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) | ||
Calibration Signal: | 1mV square wave | Protection: | Against electrosurgical interference and defibrillation |
[Heart Rate]
Measuring Range: | 20 bpm~300 bpm | Renew Time: | 1 time per beat |
Accuracy: | ±1 bpm | larm Mode: | Audible and visual alarm |
[SpO2]
SpO2% | |||
Measuring Range: | 0%~100% | Resolution: | 1 % |
Accuracy: | ±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%) | ||
Pulse Rate | |||
Measuring and Alarm Range: | 20~300bpm | Resolution: | 1bpm |
Accuracy: | ±1bpm |
[NIBP]
Method: | Oscillometric | Mode: | Manual, Auto, STAT |
Measuring Interval in AUTO Mode: | 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min) | Measuring Period in STAT Mode: | 5 min |
Cuff Pressure Range: | 0 mmHg~300mmHg | Pulse Rate Range: | 30 bpm~250bpm |
Measurement Rage: | Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg | Over-pressure Protection: | Adult 300mmHg, Pediatric 220mmHg |
Pressure Resolution: | 1mmHg | ||
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device. |
[Temperature]
Input: | Body surface thermal-sensitive resistor temperature sensor | Measuring Range: | 0℃~50℃ |
Accuracy: | ±0.1℃ |
[Storage and Review]
Maximum Data Quantity: | 3888 groups | Maximum Trend Time: | Continuous 129.6 hours |
[Printer (optional)]
Type: | Thermal micro-printer | Printer Paper: | 58 mm thermal paper,Paper roll diameter≤Φ 33mm |
Interface: | Bluetooth wireless interface | Recording Types: | Real-time printing and review data printing |
Power Supply: | |||
Rechargeable battery: | 1700mAh~2000mAh.7.2V. | Charge(discharge) : | >=1000times. |
Charge time | 2hours | Work Operation/relative humidity: | 0~55℃/10~80%RH |
Storage Operation/relative humidity: | –20~60℃/10~90%RH |
Other models for choice:
Model: PM7000A