Fixed pipeline natural gas detection monitor transmitter with IP66
USD $80 - $400 /Piece
Min.Order:1 Piece
Zhuhai Chuangan Electronic Co., Ltd.
Fixed pipeline combustible gas(natural gas )detection monitor transmitter with IP66
Fixed ozone leakage detector with ozone = 0-100 ppm Measurement Range
2016 Newest Fixed hydrogen sulfide Meter with H2S=0-100 ppm low price gas detector
fixed online smart ozone(O3) gas monitor transmitter with display screen
water treatment factory usage chlroine gas leak tester cl2 gas sensor
Fixed pipeline combustible gas(LPG)detection monitor transmitter with IP66
Fixed Gas Detector
Features:
1. Adopt advanced imported catalytic combustion sensor or electrochemical sensor
2. Reliable, sensitive and long performance life
3. High resistance to poison, good disturb-proof against
temperature and humidity
4. Automatic zero calibration can avoid long-term zero
drift caused by measurement error
5. Concentration signal output
6. Over-current protection, Anti-polarity protection
7. RS485 communication interface or 4-20mA output
8. Scope of working voltage: DC10V~DC30V
Specifications:
Detection Principle: | Catalytic Combustion or electrochemical sensor | Detection Method: | Diffused |
Applicable Gas: | Combustible Gases | Working Method: | Continuous Working |
Detection Scope: | LEL or PPM | Respond Time: | <=15S |
Detection Error: | <+-3%LEL or 1ppm | Environment Temperature: | -40°C~+70°C |
Relative Humidity: | 30%-95% | Output Signal: | Concentration Digital Signal |
Working Voltage: | DC10V~DC30V | Sensor Life Span: | 3 Years |
Transmission Distance: | <1000m | Operation Pressure: | (86-106) kPa |
Detector Size: | 158*130*93mm | Explosion-proof Level: | Exd II CT6 |
Connection Thread : | 1/2G Inner Thread | Weight: | 1kg |
Communication: | RS485 or 4-20mA | Performance Standards: | GB3836.1-2000,GB3836.2-2000,GB15322.1-2003
|
Reference Chart
Detector Model | Gas Detected | Range | Range Optional | Resolution | Responding Time |
CO Detector | CO | 0-1000ppm | 0-500/2000/5000ppm | 1ppm | 20s |
O2 Detector | O2 | 0-25%VOL | 30%VOL | 0.1%VOL | 20s |
O3 Detector | O3 | 0-10ppm | 0-100ppm | 0.01ppm | 20s |
H2S Detector | H2S | 0-100ppm | 0-50/200/1000ppm | 1ppm | 30s |
H2 Detector | H2 | 0-1000ppm | 0-5000ppm | 1ppm | 30s |
CL2 Detector | CL2 | 0-20ppm | 0-10/100ppm | 0.1ppm | 30s |
NH3 Detector | NH3 | 0-100ppm | 0-50/500/1000ppm | 1ppm | 30s |
SO2 Detector | SO2 | 0-20ppm | 0-50/1000ppm | 0.1ppm | 30s |
NO Detector | NO | 0-250ppm | 0-500ppm | 1ppm | 30s |
NO2 Detector | NO2 | 0-20ppm | 0-50/100ppm | 0.1ppm | 30s |
CH2O Detector | CH2O | 0-50ppm | 0-5/10ppm | 0.01ppm | 30s |
HCL Detector | HCL | 0-20ppm | 0-20/100ppm | 0.5ppm | 30s |
Combustible Gas Detector | EX | 0-100%LEL | 0-100%LEL | 1% | 30s |
For the gas that is not covered here though, please don’t hesitate to contact us. |