Home Solar system 12v 100ah gel battery
USD $5 - $230 /Piece
Min.Order:100 Pieces
Shenzhen Matrix Battery Co., Ltd.
Home Solar system 12v 100ah gel battery
MNG Series-- Storage-type Gelled Battery
l completely sealed and maintenance-free, low self-discharge
l 100% precise quality testing, stable quality and high reliable performance
l Unique grid alloy formula, Gelled electrolyte formula and updated manufacturing technique
l Floating & standby use:up to 12 years
l Cycle use 1: More than 350 cycles at 100% DOD
l Cycle use2: More than 1800cycles at 30% DOD
Application:
l Telecommunications
l UPS/EPS
l DC Power Supply
l Solar system
l Wind Power System
l Auto Control Sytem
Construction:
lComponent ......Raw material
lSealant ........Epoxy
lSafety valve .... Rubber
lTerminal ........Copper/Pb
lSeparator ........Fiber glass
lElectrolyte ....... Gelled acid
lPositive ........Lead dioxide
lNegative ........Lead
lContainer ........ABS
lCover ........ABS
Speification:
Battery Model | MMG 100-12 12V100AH | |||
Designed Floating Life | Up to 12 Years | |||
Capacity (25℃) | 20HR(5.2A,10.50V) | 10HR(9.8A,10.80V) | 5HR(17A,10.8V) | 3HR(2A,10.8V) |
104AH | 98AH | 85AH | 75AH | |
Dimensions | Length | Width | Height | Total Height |
407mm (16inch) | 173mm 6.81inch) | 207mm (8.15inch) | 236mm (9.29inch) | |
Approx. Weight | 32.0Kg (70.5 lbs) | |||
Internal Resistance | Full charged at 25℃:≤3.5mΩ | |||
Self Discharge | 2% of capacity declined per month at (25℃) | |||
Capacity Affected by Temp.(20HR) | 40℃ | 25℃ | 0℃ | -15℃ |
102% | 100% | 88% | 78% | |
Charge Voltage(25oC) | Cycle use | Float use | ||
14.4-14.6V(-30mV/℃), max. Current: 36.0A | 13.6-13.8V (-20mV/℃) |
Constant Current Discharge(CC,Unit:A) at 25℃(77℉) | ||||||||||||
F.V/Time | 5Min | 10Min | 15Min | 30Min | 1Hr | 2Hr | 3Hr | 4Hr | 5Hr | 8Hr | 10Hr | 20Hr |
1.85V/Cell | 209.0 | 160.0 | 135.0 | 98.0 | 56.0 | 33.30 | 23.90 | 19.70 | 16.20 | 11.41 | 9.80 | 4.85 |
1.80V/Cell | 259.0 | 205.0 | 164.0 | 105.0 | 58.0 | 34.50 | 25.30 | 20.80 | 16.30 | 11.92 | 10.0 | 5.00 |
1.75V/Cell | 266.0 | 224.0 | 171.0 | 108.0 | 59.0 | 36.80 | 25.80 | 21.30 | 16.60 | 12.12 | 10.10 | 5.20 |
1.70V/Cell | 284.0 | 230.0 | 176.0 | 110.0 | 60.0 | 37.10 | 26.30 | 21.30 | 16.60 | 12.20 | 10.20 | 5.30 |
1.60V/Cell | 318.0 | 242.0 | 183.0 | 114.0 | 62.0 | 37.60 | 27.10 | 21.80 | 17.10 | 12.42 | 10.40 | 5.50 |
Constant Power Discharge (CP,Unit:W) at 25℃(77℉) | ||||||||||||
F.V/Time | 5Min | 10Min | 15Min | 30Min | 1Hr | 2Hr | 3Hr | 4Hr | 5Hr | 8Hr | 10Hr | 20Hr |
1.85V/Cell | 397.1 | 304.0 | 256.5 | 186.2 | 106.4 | 63.3 | 45.4 | 37.4 | 30.8 | 21.7 | 18.6 | 9.2 |
1.80V/Cell | 492.1 | 389.5 | 311.6 | 199.5 | 110.2 | 65.6 | 48.1 | 39.5 | 31.0 | 22.6 | 19.0 | 9.5 |
1.75V/Cell | 505.4 | 425.6 | 324.9 | 205.2 | 112.1 | 69.9 | 50.0 | 40.5 | 31.5 | 23.0 | 19.2 | 9.9 |
1.70V/Cell | 539.6 | 437.0 | 334.4 | 209.0 | 114.0 | 70.5 | 50.0 | 40.5 | 31.5 | 23.2 | 19.4 | 10.1 |
1.60V/Cell | 604.2 | 459.8 | 347.7 | 216.6 | 117.8 | 71.4 | 51.5 | 41.4 | 32.5 | 23.6 | 19.8 | 10.5 |