Specifications
1. PES membrane2. Pore Size Range 0.03 to 20.0 um
3. Max. temperature: 130 centidegree.
Introduction
PES membrane is a highly micro porous membrane composed of modified polyethersulfone that is a tough, durable, and temperature resistant aromatic polymer. It is designed to remove particulates during general filtration, and its low protein and drug binding characteristics make it ideally suited for use in life science applications.
The membrane provides high flow rate, low extractables, and greater mechanical strength than competitive membranes. It efficiently removes particulates from solutions during general filtration. Additionally, its low protein and drug binding characteristics maximize recovery of critical drugs used in I.V. therapy, chemotherapy and open-heart surgery.
PDF [ 6 Page / 9.629KB ]
Features
- High flow rates and throughputs due to a highly asymmetric pore structure
- Inherently hydrophilic
- Low protein binding characteristics
- Good chemical compatibility
- Compatible with a variety of sealing methods
- Available in a wide range of pore sizes
- Higher wick rates (lateral flow)
- Superior burst strength
- Excellent flow rates
- Lot-to-lot and within-lot consistency
- Low extractables, no external wetting agents
- Conforming to DIN EN ISO 9001 and DIN EN ISO 46001
- Biosafety USP Class VI grade and Code of Federal Regulation, Title 21
Application
- Bacterial removal
- Blood glucose testing
- Drug filtration
- I.V.filters
- Lateral flow assays
- Particulate removal
- Serum cholesterol testing
- Plating Operations
- Food & Beverage Processing
- Ultra pure water
- Consumer Drinking Water
Technical Parameter
Pore Size[μm] | Minimum Bubble point | Water Flow Rate(≤) (seconds/100 mL H2O/9.62 cm2 at 24 inch Hg) | Burst Strength (≤N psi) | |
[psi] | [bar] | |||
0.10 | 30 | 2.1 | 130 | 18 |
0.22 | 49 | 3.4 | 30 | 16 |
0.45 | 38 | 2.7 | 21 | 16 |
0.65 | 27 | 1.9 | 17 | 10 |
0.80 | 16 | 1.1 | 8 | 10 |
1.20 | 8 | 0.6 | / | 8 |
5.00 | 5 | 0.4 | / | 8 |
Sterilization | Non Sterile. Gamma Irradiation, Ethylene Oxide(EtO), Autoclaving or Live Steam are available. |
---|---|
Endotoxin levels | <0.25 Eu/ml utilizing 400cm2/400 ml S.W.F.I per Limulus Amoebocyte Lysate(LAL) test |
Thickness | 120- 150 μm |
Typical Weight | 3.0 mg/cm2 |
Extractables | <1%(<0.015mg/cm2) |
BSA Protein Binding | <20 μg/cm2 |
Maximum Operating Temperature | 130°C(266°F) |
Sealing Compatibility | Ultrasonic, Heat, Radio Frequency and Insert Molding |
Pore Size Range | 0.03 to 20.0 μm |