Product Details

UV GAS ANALYZER SS-UV-300

Model Number SS-UV-300
Type Other

Product Features

I. Introduction

SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.).

The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gases including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions.


II. Application fields
It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.

 

III. Specifications

 

Model

Standard

Low Emission

Ultra-low Emission

Range

0-300-3000ppm

0-100-300ppm

0-20-100ppm

Linearity

≤±1.5%F.S.

Repeatability

≤±0.5%F.S.

Zero Drift

≤±2%F.S/7d

Span Drift

≤±2%F.S/7d

Response time(T90)

≤10S

≤30S

≤30S

Working Temp

-10-+40

Preheating time

No preheating

Approx.10 min

Sample Gas Interface

Ø6



Sample Gas Flow

0.5-2L/minFluctuation <25%

Sample Gas Pressure

The current encironmental pressure ±0.1 Bar

Sample Temperature

0-+50

Sample Gas Humidity

No condenstation under sample temperature

4-20mA inpt interface

3configurable100Ω load

4-20mA Output Interface

5output can be configured ,maximum load capacity <800Ω

Switch Input Interface

6, configured

Relay Output Interface

14, output ca be configured,DC30V2A

Communication Interface

1*RS232,1*RS485(support the Modbus protocol)

Installation

Installed in 19inch cabinet

Supply

220VAC±10%

Power Consumption

About 100W

About 200W


Dimension

132(H)*483W)*378(D)mm

177(H)*483W)*412(D)mm

177(H)*483W)*434(D)mm

Weight

About 10kgs

About 12kgs


 

 

IV. Product feature

1. High measurement accuracy

2. The minimum detection limit of SO2 , NO2, NO can be 1mg/m3 (15m optical path)

3. Ultraviolet has no moisture absorption, undisturbed by moisture and dust.

4. No cross interference between the gas being measured (see table 1)

5. NO and NO2 can be measured at the same time, dispense with converter

6. High reliability

7. White cell + DOAS + PLS technology, small amount of zero drift and span drift

8. Modular design

9. No optical moving parts and no vibration influence

10. Strong gas cell, low cost

11. Spectrum automatic adjustment technology, long free maintenance cycle

Light source adopts the pulse source, the service life is 10 years