Product Details

60KV - 200KV DC high voltage generators High Voltage Testing Equipment

Brand Name FINEWORK
Place of Origin China
Model Number DVPG

Product Features

Delivery Time:2 to 4 weeks
Certification:ISO, CE

Quick Detail:

Using a new double voltage material and processed by fluorine silicon Using 35-50 KHZ inverter frequency, PMW pulse width modulation With imported full shielding case and main components Adopting voltage closed-loop feedback Test leakage current under 0.75 times DC reference voltage of Zinc-Oxide Arrester. With perfect rapid protection circuit The Intermediate frequency transformer has a special design With 6 more protection functions for human

Description:

Using a new double voltage material and processed by fluorine silicon, the generator has powerful electric functions, and can be operated under very wet conditions. Using 35-50 KHZ inverter frequency, PMW pulse width modulation, small ripple factor, and light weight. With imported full shielding case and main components, the generator has a good anti-interference function and it’s very stable and reliable. Adopting voltage closed-loop feedback, the generator provides a stable voltage. Can test leakage current under 0.75 times DC reference voltage of Zinc-Oxide Arrester. With perfect rapid protection circuit, when high voltage continues discharging to ground, it causes no damage to the product The Intermediate frequency transformer has a special design, small size, and large capacity. DC high voltage generators of DHVG series have many protection functions, such as low pressure flow, low overvoltage, high pressure flow, high overpressure, zero protection, grounding protection etc, which highly improve operators’ safety.

Applications:

DC high voltage generators of DHVG series apply to DC withstand voltage test and leakage current test at site for electric power department, enterprise power department to test Zinc-Oxide Arrester , power cable, generator, transformer, circuit, breaker etc.  This kind of instruments is necessary for high voltage test.

Specifications:

Ripple factor

≤0.5 %

Voltage regulation accuracy

≤0.1%

Voltage stability

≤1%

Voltage and current measurement

4-1/2digital display meter

Voltage measurement error

1%±1 digit

Current measurement error

0.5%±1 digit

Overvoltage protection

Dial setting,1% deviation

Work Mode

Intermittent use, rated load 30 minutes

Operating ambient temperature

–10~45°C

Relative humidity (RH)

<90%

Altitude

<1000m

General Model:

Model/technical parameters

Output voltage

(kV)

Current output

(mA)

Output power

(W) 

Weight of control case

(kg)

Times the weight of the box

(kg)

Height of double voltage cylinder

(mm)

DHVG 60/2

60

2

120

3

4

φ80×470

DHVG 60/3

60

3

180

3

4

φ80×470

DHVG 60/5

60

5

300

3

4

φ80×470

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now