Product Details

EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

Type On-line
Application Other, telecom/financialsystem/industrial system/Transportation systems

Product Features

EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

 

EverExceed safe and reliable UPS power products:

 

online / off-line UPS, high frequency online UPS, low frequency online UPS, modular online UPS, etc. We also offer customized services to meet various customers’ need.

 

 

Why choose us?

 

1) Nearly 30 years leading manufacturer;

2) Worldwide brand registered in more than 70 countries;

3) Comprehensive certificates approval: TUV / VDE / CE / ISO / IEC / DEKRA / ROHS

4) Strict management system and quality control, 100% inspection

5) A professional experienced team to provide you high-quality service.

 

EverExceed PowerNX Series Online UPS

 

Voltage:10-200KVAEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

 

3:3 phase  

                                                               

 

 

 

 

 

 

 

 

 

 

 

Product Description

The innovative design of the PowerNX makes it one of the most technologically advanced UPS of its kind. Exclusively developed by EverExceed, the PowerNX series UPS delivers an advanced combination of low input current distortion, uni- ty power factor input, high overall efficiency and maximum load protection ensuring ultimate power quality. This sophisticated arrangement of features make this series ideal for criticalapplications where reliability and high perfor-mance are fundamental. In addition, the PowerNX comprises an IGBT input rectifier design with dual DSP (Digital SignalProcessing) ,which provides full digital control. The PowerNX configuration guarantees high quality output required by loads requiring a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Sys-tems. VFI (Voltage & Frequency Independent) Online Double Con-version topology, provides built-in inverter galvanic protec- tion, completely isolating the output of the UPS from mains power problems and further protection is achieved via anintegral output isolation transformer. This advanced design

offers an extensive range of user benefits, delivering high efficiency without compromising load protection.

 

EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

Features

 

  1. On line double conversion
  2. IGBT input rectifier
  3. High efficiency
  4. Isolation transformer based
  5. Life-prolonging battery management

 

 
EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System 
Applications

 

  1. Data centers
  2. Process control equipment
  3. Internet service providers
  4. Transportation systems
  5. Broadcasting and entertainment
  6. Telecommunication installations
  7. Financial systems
  8. Credit card operations
  9. Medical/healthcare
  10. Industrial systems
  11. Server farms
  12. Security operations

 

Specification

 

Certification

EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System 

 

Related products

 EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

 

Company Information

 

EverExceed Group was established in 1980s and has its headquarter in Shenzhen, China, and subsidiaries in Singapore, UK and operations in six continents. We are manufacturing and supplying worldwide reliable power solutions with continuous innovative technologies, cost-effectiveness and good service, including industrial batteries (lead acid batteries, NiCad batteries, Lithium-ion batteries), solar power systems, UPS systems and DC power systems.

 

EverExceed attained the certificates of ISO9001 & ISO14001, and our products are accredited with TUV / VDE/ CE/ IEC/ UL/ RoHS/ DEKRA. Our advanced technology, professional technique, automatic equipment, experienced staff and strict operation system assure high level product quality. By now, reliable products with our brand “EverExceed” have been exported to more than 60 countries all over the world.

 

Warmly and sincerely welcome you to join us, and become a distributor and a partner in the future.

 

For more information, please visit our website:www.everexceed.com.

 EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial SystemEverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

FAQ

Q:How does the on-line UPS normal work principle?

A: The input converter and output inverter shall operate in an on-line manner to continuously regulate power to the critical load. The input and output converters shall be capable of full battery recharge while simultaneously providing regulated power to the load for all line and load conditions within the range of the UPS specifications. 

Q:What’s the meaning of UPS’s battery mode?

A:Upon failure of the AC input source, the critical load shall continue being supplied by the output inverter, which shall derive its power from the battery system. There shall be no interruption in power to the critical load during both transfers to battery operation and retransfers from battery to normal operation.

 

Q :What’s the meaning of UPS’s bypass mode?

A:The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source. This transfer, along with its retransfer, shall take place with no power interruption to the critical load. In the event of an emergency, this transfer shall be an automatic function.

 

Q: What’s the meaning of UPS’s THDi?

A: The input current THDI(Total Harmonic Distortion) shall be held to 5% or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or non-linear type. This shall be accomplished with no additional filters, magnetic devices, or other components.

Q:What’s the meaning of UPS’s overload capacity?

A:Steady-state overload conditions, of up to more than 100% of system capacity, shall be sustained by the inverter for several seconds in normal and battery operation. Should overloads persist past the outlined time limitation the critical load will be switched to the automatic static bypass output of the UPS.

 

Tags: homage ups,luminous ups,ups power supply,solar ups,online ups,ups systems,line interactive ups,networking ups,single phase ups,3 phase ups,dc – ups,Uninterrupted power supply

Keyword: ups,uninterrupted power supply

EverExceed Low Frequency GBT input rectifier 1-200KVA Three Phase UPS PowrNX For Financial System

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now