Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer
1.Application
This combined instrument transformer is for use with electrical measuring instruments and electrical protective devices. It consists of a current transformer and a voltage transformer in the same case.
Our combined instrument transformer is especially suitable for HV metering, to do so, two voltage transformers shall be connected in V type, while two current transformers connect serially to phase A and C. The instrument transformer can be fixed on the post of transmitting line. The secondary output connects directly to an independent HV metering box. Users can choose certain connection in accordance with different conditions.
1).Rated Voltage (kV): up to 35kV
2).Rated Primary Current: up to 1000A or custom specified
3).Rated Secondary Current: 5A
4).Accuracy Class: up to 0.2s for metering; up to 0.2, 0.5 for protection
5).Rated Frequency: 50Hz (60Hz on request)
6).Installation: outdoor
7).Insulation Material: epoxy resin and silicon jel
8).Winding: high quality enameled copper wire
* Except for the technical parameters list above, we can design as per clients’ requirements.
1).A metering unit consisting of one CT and one VT
2).With small volume and good performance
3).Multi-taps at the secondary windings, which makes different current transformation ratio for the current exchange of customers while power consumption increasing
4. Manufacturing Standard: IEC60044-3:2002, GB17201-2007
5.Technical Parameters for JLSGW-35III Metering Devices
Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer
Technical Parameters Table
Items | Frequency : 50Hz Phase Number: Three-phase | ||
VT | Rated Voltage Ratiok V/kV | 3, 6 or 10/0.1 | |
Three-phase Metering Connection | Two voltage transformers shall be connected by V/V | ||
Accuracy Class | 0.2 | 0.5 | |
Rated Secondary Output (VA) | 15~50 | 30~50 | |
Limit Output (VA) | 350 | ||
Secondary Burden Power Factor | 0.8 (lag) | ||
CT | Rated Current Ratio (A/A) | 5~400/5 | |
Rated Extension Primary Current (%) | 200 | ||
Three-phase Metering Connection | Primary terminals of two current transformers shall be connected seriesly to phase A and C | ||
Accuracy Class | 0.2S | ||
Rated Output (VA) | 10~40 | ||
Secondary Burden Power Factor | 0.8 (lag) | ||
Rated Short-time Thermal Current (r.m.s) Ith (kA) | 100 Ith | ||
Rated Dynamic Current (Peak) Idyn (kA) |
2.5 Idyn |
Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer
Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer:
For the low voltage products: | 5 -10 days |
For the medium voltage products: | 10 -15 days |
For the high voltage products: | 20 -30 days |
Payment: | T/T or L/C |
Port: | Guangzhou |
Packing: | Wooden case |
And we have a team who is in charge of packing. The team consists of our skilful carpenters and experienced packing designers. These enable our packing reasonable, safe and reliable.
Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer
- Your inquiry related to our product & price will be replied within 24hours
- Well-trained & experienced staff are to answer all your inquiries in English of course.
- Working time: 8:00am ~17:45pm, Monday to Saturday. (UTC+8).
- Provide perfect after-sale service, if you got any question, please contact with us and we wll solve your problem immediately.
- We have our own transportation department, goods can be delivered on time whenever they are ready.
- Your business relationship with us will be confidential to any third party.
Coated With Epoxy Three Phase Combined Type Voltage and Current Transformer