Product Details

IEC61000-4-2 20KV Output Voltage Electrostatic Discharge Generator

Place of Origin China
Model Number ESD-2000WA
Power Electronic

Product Features

IEC61000-4-2 20KV Output Voltage Electrostatic Discharge Generator 

1. Introduction:

The electrostatic discharge generator can meet the test requirements of IEC61000-4-2 and GB/T17626.2. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. 

Electrostatic discharge immunity test is a basic EMC test, the ESD generator is a special equipment to conduct ESD test, it consists by ESD generator, ESD gun, electrodes (cone sharp electrode is for contact discharge, and ball sharp electrode is for air discharge) and control PAD. The discharge resistance 330Ω and energy storage capacitance 150pF are built-in the ESD gun, and they can easy to replace to meet different product standards. 


2. Features:

1). The air discharge completely meet the standard requirement to keep the voltage for 5s above, and do not affect by air humidity, with good repeatability.

2). Remotely control the test by PAD, safer operation.

3). HV protection, over current protection and short circuit protection.

4). Updated system can automatically identify air discharge.

 

3. Parameters:

Model

ESD-2000WA

ESD-2005WA

Output voltage

Contact discharge

0.120kV ±3%

0.130kV ±3%

Air discharge

0.120kV ±3%

0.130kV ±3%

Holding time

>5s

Output Polarity

Positive, negative, positive and negative cycle, positive and negative alternation, positive first then negative, negative first then positive

Trigger mode

SINGLE

Single discharge

COUNT

Discharge according to the set discharge times

20pps

The discharge interval is fixed at 20 times/s

Other

Host self-triggering, voltage automatic gradual scanning, program control, etc.

Discharge mode

contact discharge, air discharge

Discharge interval

0.05~99s (0.05s @ 20pps)

Numbers of discharge:

1~9999 times

Energy storage capacitance

150pF ±10% (replaceable)

Discharge resistance

330Ω ±10% (replaceable)

Waveform of contact discharge

Meet the standards of EN/IEC 61000-4-2, GB/T 17626.2

Rising time:

0.8ns ±25%

First peak current

7.5A ±15% @ 2kV

7.5A ±15% @ 2kV

15A ±15% @ 4kV

15A ±15% @ 4kV


22.5A ±15% @ 6kV

22.5A ±15% @ 6kV

30A ±15% @ 8kV

30A ±15% @ 8kV

Current at 30ns

4.0A ±30% @ 2kV

4.0A ±30% @ 2kV

8.0A ±30% @ 4kV

8.0A ±30% @ 4kV

12.0A ±30% @ 6kV

12.0A ±30% @ 6kV

16.0A ±30% @ 8kV

16.0A ±30% @ 8kV

Current at 60ns

2.0A ±30% @ 2kV

2.0A ±30% @ 2kV

4.0A ±30% @ 4kV

4.0A ±30% @ 4kV

6.0A ±30% @ 6kV

6.0A ±30% @ 6kV

8.0A ±30% @ 8kV

8.0A ±30% @ 8kV

Working conditions

Temperature:15°C35°C;Humidity:10%75%

Input

AC220±10%50/60Hz, 300W

Dimension and weight

260mm(W)×170mm(H)×360mm(D) /6KG

 

4. ESD test bench (prepare by user)

Name

size

quantity

Ground reference plane (GRP)

2800mm*1800mm*1.0mm
(Length*Width*Thickness)

1

Wooden table

1600mm*800mm*800mm

(Length*Width*Height)

1

Horizontal coupling plane (HCP)

160mm*800mm*1.0mm

(Length*Width*Thickness)

1

 

Vertical coupling plane (VCP)

500mm*500mm*1.0mm

(Length*Width*Thickness)

1

 

Insulating support

1450mm*600mm*0.5mm

(Length*Width*Thickness)

1

Earth cable (come with equipment)

2m length

2

bleeder resistor (come with equipment)

470kΩ×2

2