Product Details

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath

Product Features

DWC 40/60/80/100  Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath  

 DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath

Product Description

 

1. Application

The mechine is designed according to Charpy notch Impact Test Method for Metal Material, and adopts compressor cooling technology. It utilizes the heat balance principle and cycle stirring method to realize the constant temperature cooling to impact specimen with the reliable performance. Digital display, automatic control temperature, and it is the ideal equipment for cooling and keeping temperature to impact specime

 

2.Features:

2.1Imported compressor, DANFUS valve, imported evaporation-condensation machine;

2.2Controlled by intellligent instrument, digital presentation temperature value, automatic control temperature, automatic time and alarm.

2.3high security, refrigerate fast, large volume

 

3.Main Specifications:

 

Model

DWC-40

DWC-60

DWC-80

 

DWC-100

Temperature range

+30~-40°

+30~-60°

+30~-80°

+30~-100°

Temperature Control Accuracy

±0.5°

Temperature dropping speed

 

+30°C~0°C

1.2°C/min

+30°C~0°C

2°C/min

+30°C~0°C

2°C/min

+30°C~0°C

2°C/min

0°c~-20°C

0.8°C/min

0°c~-20°C

1.5°C/min

0°c~-20°C

1.5°C/min

0°c~-20°C

1.5°C/min

-20°C~-40°C

0.5°C/min

-20°C~-40°C

1.0°C/min

-20°C~-60°C

1.0°C/min

-20°C~-40°C

1.0°C/min

-40°C~-60°C

0.7°C/min

-60°C~-80°C

0.7°C/min

-60°C~-100°C

0.7°C/min

Cold Room Volume

150×505×240mm

Dimensions

900×505×850 mm

 

900×505×850 mm

 

900×505×850 mm

 

1500×1200×1200 mm

 

Box Material

Steel Spray

Loading the number of samples

>60

>60

>60

>200

Mode of refrigeration

Compressor refrigeration

Cooling Medium

Ethanol or other unfrozen liquid

Power

7Kw

7Kw

7Kw

7Kw

 DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath

More Information

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now