Product Details

ST2241 Grounding resistance Tester/ earth resistance measurement/ soil resistivity meter

Product Features

ST2241 Grounding resistance Tester/ earth resistance measurement/ soil resistivity meter

Product Description

ST2241 Grounding resistance Tester/ earth resistance measurement/ soil resistivity meter

1.Basic introduction

Product Name: High Quality Error Small grounding resistance earth tester digital, Multi-function earth resistance clamp meter

Function: grounding resistance, soil resistivity;Ground voltage, AC voltage measurement

Soil Resistivity Range: 0.00Ωm~1kΩm

Resistance Range: 0.00Ω~100.0kΩ

Voltage Range: AC 0.0~600V

Measurement Method: precision four-wire, three-wire measurement, simple two-wire measurement

Line Voltage: measure below AC 100V

Application: ST2241 soil resistivity earth resistance tester is adopted the latest digital and micro-processing technology and can accurately detect ground resistance, soil resistivity, and ground voltage. It uses a fast filtering technique to minimize interference. Displaying the resistance value of the auxiliary electrode in the same screen, which is convenient for judging the measurement error caused by environmental factors, facilitating more accurate measurement of the grounding true resistance value.Widely used in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding networks, lightning rods and so on. The instrument has the characteristics of precise, fast, simple, stable and reliable.

 

2.Technical Parameters

2.1 Baseline and working conditions

 

Impact

Benchmark condition

Working conditions

Note

Auxiliary grounding resistance value

<100Ω

 <100kΩ

rC, rP

Electrode distance when measuring R

 a> 5d

a> 5d

----

Electrode distance when measuring ρ

a>20h

a>20h

----

Ambient temperature

23℃±1℃

-10℃~40℃

----

Environment wet crossing

40% ~ 60%

<80%

----

  

2.2.General specifications

Function

Two, three or four wires measure ground resistance and soil resistivity;Ground voltage, AC voltage measurement

Power supply

DC 8.4V (2 rechargeable lithium batteries)

Range

Ground resistance: 0.00Ω~100.0kΩ

Soil resistivity: 0.00Ωm ~ 1kΩm (then multiplied by the coefficient 2πa)

Measurement method

Precision 4-wire, 3-wire measurement, simple 2-wire measurement of ground resistance

Short-circuit test current

AC ± 20mA max

Open circuit test voltage

AC ± 20V max

Test voltage waveform

square wave (1KHz)

Electrode pitch range

can be set from 1m to 10m

Standard test line

4 strips: 2 strips of 20m length, 2 strips of 10m length

Simple test lead

2 strips: 1.0m yellow, 1 each green 1.0m

Auxiliary ground rod

4 pieces:φ10mm×150mm

Line voltage

AC 600V or less

USB interface

With USB interface, software real-time monitoring, stored data can be uploaded to the computer, save and print, soil layer analysis and other functions

Communication line

1 USB cable, 1.5m long

Auxiliary ground test

With auxiliary ground resistance value test function, but must meet R + rC<50kΩ, R + rP <50kΩ R is the measured ground resistance

Working temperature and humidity

-10℃~40℃;

Storage temperature and humidity

-20℃~60℃; 

 

 

2.3.Basic error and performance index under reference conditions

 

Measurement function

Measuring range

Precision

Resolution

Ground resistance(R)

0.200Ω~2.000Ω

±5%rdg±5dgt

0.001Ω

02.00Ω~20.00Ω

±2%rdg±3dgt

0.01Ω

020.0Ω~200.0Ω

±2%rdg±3dgt

0.1Ω

0200Ω~2000Ω

±2%rdg±3dgt

02.00kΩ~20.00kΩ

±5%rdg±5dgt

10Ω

Soil resistivity(ρ)

depends on the measurement range of R

(ρ=2πa(R÷100)   a:1 m~100m;π=3.14)

(ρmin = 1.256Ωm , ρmax = 125.6KΩm )

Ground voltage

AC 0.0~600V

±2%rdg±3dgt

0.1V

 

Note: 1. When rC or rP is larger, the additional error is ≤ ± 3% rdg ± 5dgt.(rC max<50kΩ; rP max <50kΩ)