ASTM D924 Laboratory Equipment Tan Delta Tester / Mini Movable Dielectric Loss Tester

Product Features

Product Description



ASTM D924 Laboratory Equipment Tan Delta Tester / Mini Movable Dielectric Loss Tester




Introduction
TP-6100A Insulating oil dielectric loss and resistivity tester is based on ASTM D 924, IEC and GB/T5654-2007. It is used for testing dielectric loss factor and DC resistivity of insulation oil and other liquid insulating medium.
The instrument is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge,

AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. It is equipped with large screen (240*128) LCD display. The test results can be automatically stored and printed out so that the operator with no professional training will be able to use it easily.


Features
1. Grease cup complies to national standard GB/T5654-2007; three-electrode structure; inter-electrode space of 2mm; eliminate stray capacitance and leakage effects on dielectric loss test results.
2. Adopts the medium frequency induction heating and PID temperature control algorithm with advantages of non-contact oil cup and heating body, even heating, fast speed, convenient control, strict temperature control.
3. Internal standard capacitor of SF6 gas-filled three-electrode capacitance of the capacitor dielectric loss and electrical capacity independence of ambient temperature, humidity and other effects. The instrument accuracy is ensured even after prolonged use.
4. AC test power supply using AC-DC-AC conversion to effectively avoid fluctuations in mains voltage and frequency effect on dielectric loss measurement accuracy. Even a generator, the instrument can work properly.
5. Perfect protection function. When there is over voltage, over current or high-voltage short circuit, instrument can quickly cut off pressure and issues a warning message. When the temperature of the sensor fails or is not connected, the instrument will also issue a warning message.
6. There is a temperature limit relay in the medium frequency induction heating furnace. When temperature is above 120 degrees, the instrument frees the relay and stops heating.
7.More convenient the experimental parameter is set.Temperature setting range 0~125℃, AC voltage setting range 500~2200V, DC voltage setting range 0~500V.
8. With large screen LCD with backlight and clear display. Friendly interface; Enter the commands, the instrument will automatically test, store and print test results.
9. Built-in real-time clock. Test date ans time can be retained with the test results, display and print.
10. Air electrode cup calibration function. Measurement air electrode cup capacitance and dielectric loss factor in order to determine air electrode cup cleaning and assembly condition. The calibration data is automatically saved in order to facilitate the calculation of relative permittivity and DC resistivity.

Technical Parameters


Power supply: AC220V±10%, 50Hz/60Hz ±1%


Measuring range:
Electric capacity 5pF~200pF
Relative capacitivity1.000~30.000
Dielectric loss factor0.00001~100
DC Resistivity2.5MΩm~20TΩm


Measuring accuracy:
Electric capacity± (1% of reading +0.5pF)
Relative capacitivity±1% of reading
DC Resistivity±10% of reading


Resolution:
Electric capacity0.01pF
Relative capacitivity0.001
Dielectric dissipation factor0.00001


Measured temperature range:0~125℃
Temperature measurement error:±0.5℃
Test Voltage AC(RMS):500~2200V Continuously adjustable, frequency 50Hz
Test Voltage DC:0~500V Continuously adjustable
Power dissipation:100W


Dimension:500×360×420mm
Weight:22Kg


Working conditions:
Ambient temperature:0℃~40℃
Relative humidity(RH):<75%

Detailed Images
Related Certificates

 

Key words(TP-6100A): dielectric loss test, insulating oil dielectric loss tester, dielectric loss transformer oil tester, dielectric loss testing testing equipment, dielectric loss meter, insulating oil loss tester, transformer oil tester, oil dielectric loss tester, transformer dielectric loss, oil current resistivity tester, oil resistivity, oil loss factor tester, oil dielectric loss test, loss factor,power factor measure,tan delta tester,transformer oil loss tester,Dielectric Dissipation Factor (Tan delta) IEC standard, Dielectric Constant IEC standard,Resistivity (Ohm. cm) BS standard

FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, Alibaba Trade Assurance etc.
Payment terms: Generally, T/T 40% advanced, the balance paid by T/T when the machine is ready; or 100% irrevocable L/C at sight.

What are the available delivery methods?
Our port location: Chongqing, Shanghai or other main port of China
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 10 ~ 20 days; test equipment or analyzer delivery date is around 5~10 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 2 years after start up of the system.

How is the technical services on the product?
Engineer available to service machinery overseas. If you have any technical question, you are welcome to contact us any time. We will response promptly and answer to your satisfaction. If required and necessary, we can send our engineer to your place to provide technical support.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now