Product Details

Powder Bulk Density Meter For Activated White Clay

Product Features

TP-23771 Bulk Density Tester

The powder bulk density meter is equipped with a leveling device that adjusts the balance to reduce the influence of the external environment on the measurement results; the measuring cup has a positioning device to ensure that the center of the funnel and the measuring cup are in a straight line. It is designed and produced according to the national standard GB/T 25571-2010 food national safety standard, food additive active clay. The device is suitable for the determination of the bulk density of activated white clay for food additives. It also meets the HGT2764-2008 industrial sodium percarbonate industry standard for bulk density determination equipment requirements. It also meets the determination of bulk density in GBT 23771-2009 inorganic chemical products. HG/T2573-2006 industrial light magnesium oxide (HGT2573-2006 instead of HGT2573-1994) bulk density determination requirements; at the same time meet HG/T2770-2008 industrial ammonium polyphosphate, mainly used as coatings, paper, plastics, rubber Determination of bulk density of flame retardant additives for textiles, wood and organic building materials.
The principle of powder bulk density meter: the dust is freely dropped from the funnel mouth at a certain height and filled with the measuring cup; the mass per unit volume in the measuring cup under the loose state is determined, that is, the bulk density. The sample to be tested is loaded into the funnel, falls naturally along the lower port of the funnel and flows into the measuring cylinder, and the sample falling into the measuring cylinder is flattened, and the quality of the sample in the measuring cylinder is measured after being flattened on the balance. By dividing the volume of the measuring cylinder, the bulk density of the product to be tested can be measured.
Instrument structure: 1: The funnel outlet is 30 mm in diameter; the height of the funnel is 135 mm, and the funnel is made of stainless steel. 2: Measuring cylinder diameter: 80mm, volume: 500ml
Measurement methods 1. Preparation of sample: The sample to be tested was placed in an oven and dried at a temperature of 1100 C for 1 hour and cooled to room temperature before measurement. 2. Fill the sample to be tested with a 250 mL beaker. Close the vent of the funnel and place the measuring cylinder in the center of its outlet. Pour the sample into the funnel and open the discharge valve of the funnel to allow the abrasive to fall freely until it has completely flowed. This process should avoid vibration. 3. Use a straight ruler to scrape off the excess sample on the measuring cylinder. When the material is scraped, the ruler is about 450 degrees from the upper plane of the measuring barrel and scraped four times perpendicularly to each other. This process should prevent compaction of the specimen in the measuring cylinder and avoid chattering. The mass of the sample in the measuring bucket is then weighed. 4. Calculate the bulk density as follows: Pam1/V where: Pap ------- the bulk density of the sample to be tested, unit: g/cm3; M1-------- Measure the mass of the sample in the cylinder, unit: g; V--------- measure the volume of the cylinder, unit: cm3. 5. A sample shall be measured three times repeatedly, and the arithmetic mean of the three measurements shall be taken as the bulk density value of the sample to be tested. 6. The same operator repeats the measurement with the same instrument, and the error shall not exceed ±0.02g/cm3.

1.1.Fully Automatic Karl Fischer Water Content Tester TP-2100
2.Digital Karl Fischer Water Content Tester TP-6A
3.Kinematic Viscosity Tester VST-2000
4.Kinematic Viscosity Tester TPV-8
5.Kinematic Viscosity Tester VST-3000
6.Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
7.Fully Automatic Surface/Interface Tension Tester IT-800

8.Automatic Surface/Interface Tension Tester (Platinum Plate Method) IT-800P
9.Fully Automatic Open Cup Flash Point Tester TPO-3000
10.Fully Automatic Closed Cup Flash Point Tester TPC-3000
11.Digital Open Cup Flash Point Tester TPO-100
12.Digital Closed Cup Flash Point Tester TPC-100
13.Cloud Point & Pour Point Tester PT-2000

MOQ
1 Set
Trade Terms
EXW, FOB, CIF, CFR
Payment Terms
T/T, L/C
Port of Loading
Any Port of China
Packing Method
Internaional Standard Wooden Case
Transportation Method
By Sea, By Land, By Air, By Express
Supply Capability
100 Sets/Month

* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.

Chongqing TOP Oil Purifier Co., Ltd

Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc.

Welcome to visit our website, welcome your inquiry.

Mia (Miss) | Sales Manager
CHONGQING TOP OIL PURIFIER CO.,LTD
Manufacture oil purifiers and supply test equipment.
Add: No. 1, Jianlong N. Rd., Jiulongpo District, Chongqing, China
E: sales10@topoilpurifier.com
Cell: 0086-13983286435 (Whatsapp/Wechat) | Skype: topoilpurifier
Tel: 0086-23-88901306 | Fax: 0086-23-88901306
www.topoilpurifier.com; www.toptester.com.cn

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now