Product Details

Programmable Hipot and Insulation Resistance Tester (JQ-7122)

Place of Origin Guangdong, China
Brand Name JIANQIAO
Model Number JQ-7122
Power Electronic
Usage Other, Insulation Resistance Tester

Product Features

Specifications

Hipot and Insulation Resistance Tester
Applies for the testing of IEC61730-2 standard

 

Multichannel Withstanding Voltage Insulation Tester

Brief Introduce

 JQ-7122 are the withstanding voltage insulation tester of multichannel scanning, composed of a master controller and a scan box. They can output AC/DC withstanding voltage insulation testing voltage in four-way, eight-way or sixteen-way respectively, conducting time sharing scanning test of several channels and testing the channels at the same time. What’s more, they can rapidly and accurately measure the withstanding voltage insulation tests of electronic components, household electrical appliances, transformers, lighting electrical appliances, electric tools and heating appliances, improving the testing efficiency.

Features

The output voltage rises, remains and declines as per the time gradient
The parameter tests of AC withstanding voltage,DC withstanding voltage and insulation resistance 
Successive testing of single channel can be realized, as well as the time sharing scanning test of several channels and testing of several channels simultaneously.
10 groups of measuring memory models
Arc detection function
Man-machine dialogue operation interface 
Simple connection and ease of use

 

 

 

Model

JQ-7122

Output Voltage

0~5kV(AC)
0~6kV(DC)±(2%+5V)

High limit of AC current

0.10~12.00mA
±(2%+2Counts)

Low limit of AC current

0.00~12.00mA>
±(2%+2Counts)

High limit of DC current

0.10~5.00mA
±(2%+2Counts)

Low limit of DC current

0.00~5.00mA
±(2%+2Counts)

Test voltage of insulation resistance

100~1000kV
±(2%+5V)

Insulation resistance

Only available for 7112S
Range (1-1000)MΩ
Accuracy ±(2%±2Counts) Voltage≥500V DV
±(5%±2Counts) Voltage<500V DV
Range (1000-9999)MΩ
Accuracy ±(5%±2Counts) Voltage≥500V DV
±(10%±2Counts) Voltage<500V DV

LCD

16×2 lines apheliotropic LCD

Test Time

0.1~999.9s
±(2%+0.05sec)

Remote control equipment

Input:Test,Reset Output:Pass,Fail,Test-in-Proess

Alarm

Beeper, indicator

Calibration mode

Software calibration

Memory

Set values of voltage, current ,resistance, time memorized

Temperature/Humidity

0C~40C≤75%RH

Dimensions/Weight

W×H×D:280mm×100mm×370mm / 10kg

Standard accessories

 

 

 

 