Product Details

PID Temperature Controller CD901

Place of Origin Zhejiang, China
Brand Name Neutral
Model Number CD901
Usage Industrial
Theory Temperature Controller

Product Features

Specifications

Digital PID Temperature Controller CD901
Inut type: Unversial Input (K,J,E,R,Pt100,Cu50,4-20mA,etc.)
Control precision:+-0.2%

CD series Digital Temperature Controller

   ♦ Industrial standard microcomputer processor

   ♦ Auto adjusting function

   ♦ Big screen LED display

   ♦ Heating/Cooling control

   ♦ Digital communication

 

Model Name:

PID Temperature Controller CD901 

(1)Outline dimension

See the outline dimension picture

 

(2)Control Mode

F:PID operation and auto calculating (reverse operation)

D:PID operation and auto calculating(Forward operation)

W: heating/cooling PID operation and auto calculating(cooling water)*1

A: heating/cooling PID operation and auto calculating(cooling wind)*1

(3)Input mode

Refer to Input Range Table

 

(4)Range Code

Refer to Input Range Table

 

(5)First control output(OUT1)

(Heating side)

M: Relay contact output

8: Current output(IC4-20mA)

V: Voltage impulse output

G: Thyratron driving & triggering output

T: Thyratron output

 

(6)Second controloutput (OUT2)

(Cooling side)*2

No mark: when the control mode is F or D

 

M: Relay contact output

T: Thyratron output

V: Voltage impulse output

8: Current output(IC 4-20mA)

 (7)First alarm

(ALM1)

 

 

(8)Second alarm

(ALM2)*2

 

N: no alarm

 

A: Upper-limit deviation alarm

J: lower-limit input alarm

B: Lower-limit bias alarm

K: Standby upper-limit input alarm attached

C: Upper/lower limit bias alarm

L: Standby lower-limit input alarm attached

D: alarm in area

P: Heater line breakage alarm(CTL-6)*3

E: Standby upper-limit bias alarm attached

S: Heater line breakage alarm(CTL-12)*3

F: Standby lower-limit bias alarm attached

R: Control line breakage alarm *4

G: Standby upper/lower limit bias alarm

V: Upper-limit setting alarm

H: Upper-limit input value alarm

W: Lower-limit set value alarm

(9)Communication*5

N: No communication

 

(10)Water-proof/dust-proof

N: no water-proof/dust-proof

 

 

Refer to Input Range Table  

 

Input type

Set range

Input type

Set range

(TC)

Thermocouple Input(TC)

K

0 to 1372°c(0 to 2502°F)

J

0 to 1200°c(0 to 2192°F)

R

0 to 1769°c(0 to 3216°F)

S

0 to 1769°c(0 to 3216°F)

B

0 to 1820°c(0 to 3308°F)

E

0 to 1000°c(0 to 1832°F)

N

0 to 1300°c(0 to 2372°F)

T

-199.9 to +400.0°c(-199.9 to +752.0°F)

W5Re/W26Re

0 to 2320°c(0 to 4208)

PL

0 to 1390°c(0 to 2534°F)

L

0 to 900°c(0 to 1652°F)

U

-199.9 to +600.0°c(-199.9 to +999.9°F)

RTD Input

Pt100Ω(JIS/IEC)

-199.9 to +649.0°c

(-199.9 to +999.9°F)

JPt100Ω(JIS)

-199.9 to +649.0°c

(-199.9 to +999.9°F)

Voltage input

0 to 5V DC

 1 to 5V DC

-1999 to +9999(programmable range)

Current input

0 to 20mADC

4 to 20mADC 

-1999 to +9999(programmable range)

 

 

 

 

 

 

 