Type | Model | Graduation | Range(℃) | Accuracy | Allowable error delta t |
|
|
|
| II | ±1℃or ±0.75%t |
Platinum resistance | WZPT | Pt100 | -200-500 | A | ±(0.15+0.002t) |
B | ±(0.30+0.005t) | ||||
Copper resistance | WZCT | Cu50 | -50-100 | II | ±(0.30+6.0X10-3t) |
Bearing thermal resistance
Name | Model | Graduation | Measure range | Protection tube length L mm | Accuracy | Response time |
Bearing platinum resistor | WZPT-31 | Pt100 | 0~200℃ | 100 150 200 250 300 | B | T0.5≤20s |
Our factory is a professional manufacture producing temperature measuring instruments, with our country electric power industry development, various thermocouple and thermal resistance applicable to power plant are required. Our factory in order to catch up with the international industrial instruments level, save the country foreign exchange as well, has introduced from abroad the professional manufacturing technology and equipment, and on the basis of original products, widely accepts the design institute and the opinions of the power users, in accordance with JB/T9238-1999 and JB/T8622-997 standard.