Product Details

K type thermocouple for temperature instrument

Place of Origin Liaoning, China
Brand Name Beixing
Model Number WR
Usage Industrial
Theory Temperature Sensor

Product Features

Specifications

1.Easy assembly and convenient for replacement
2.High mechanical strength and good pressure-resistant performance

Assembly type thermocouples

Application                                    
As sensor for temperature measuring and regulation, assembly thermocouples is usually connected with display meter and other meters to directly measure temperature of liquid, vapor, gas and solid surface ranging from -40°C to 1800°C.


Features                              
1.Easy assembly and convenient for replacement.
2.Spring thermal element with good shock-proof performance.
3.Wide measuring range.
4. High mechanical strength and good pressure-resistant performance.


Principle                                            
Thermocouple is based on physical phenomenon that two conductor of different materials is connected to form return circuit, when temperature on both contact is different, it results in thermoelectric potential in return circuit.
Assembly thermocouple is usually composed with temperature sensing element, Mounting & Fixing device and Junction Box.

 

Main technical parameter                                       
Measuring range and Tolerance 

Type

Graduation

Measuring range °C

Tolerance class

ClassⅠ

Class Ⅱ

NiCr-NiSi

K

-40~850

±1.5°C

or ±0.4%t

±2.5°C or ±0.75%t

Simplex -40~1200

Duplex  -40~1000

Nicr-Konstantan

E

Simplex -40~650

Duplex  -40~550

PtRh10-Pt

S

0~1600

±1.5°C or ±0.25%t

PtRh30-PtRh6

B

0~1800

Class Ⅲ ±3°C or ±0. 5%t

 

Thermal response time 

Protection tube diameter (mm)

Protevtive tube material

Thermal response timeτ(0.5)S

Φ16

high Al content tube/ corundum tube

≤240

metal tube

≤180

Φ20

metal tube

≤240

Φ25

high Al content tube/ corundum tube

≤300

tapered protection tube

metal tube

 

 Normal temperature insulation resistance

Length

Normal temperature insulation resistance

Testing voltage

L≤1m

≥100MΩ

500±50V DC

L>1m

≥100 MΩ.m/L

 

Remark: Please identify the following items when ordering:
1. Shutter support Specification
2. Single-ouch or double-ouch
3. Lead Wire Length
4. Lead Wire Material
5. Protection material
6. Protection length
7. Stainless steel armor tube material
8. Stainless steel armor tube length
9. Spring material, ID, OD and length

 K type thermocouple for temperature instrumentK type thermocouple for temperature instrumentK type thermocouple for temperature instrument