MODEL | TG-30B1-XA3040-070-AS/CE | |||
Input | Input Voltage | 180VAC~264VAC | ||
Rated input voltage | 220VAC | |||
Start-up Voltage(-25~70°C) | 180VAC | |||
Frequency Range | 50Hz | |||
Power Factor(@25°C) | >0.90@220VAC, Full Load. | |||
AC Current (@25°C) | 0.3A Max. | |||
Inrush Current (@ 25°C) | 50A Max. | |||
Output | Output Voltage Range | 30V~40V | ||
Output Current | 700mA;±5% (without dimmer, input 220Vac) | |||
Output Power | 21~28W | |||
Conversion Efficiency (@25°C) | 85% @220VAC, Full Load. | |||
No-load Output Voltage | 45V Max. | |||
Line Regulation (@-25~70°C) | ±5%@220Vac,50Hz | |||
Accuracy Constant(@-25~70°C) | ±5%@220Vac,50Hz | |||
Set-up Time(@25°C) | <1S@220VAC, | |||
Temperature Coefficient(@-25~70°C) | ±0.03%/°C | |||
Overshoot (@-25~70°C) | ±5% No-load Rated Voltage. | |||
Output Ripple & Noise | 0<Ta≤70°C | <500mVP-P | ||
-25≤Ta≤0°C | / | |||
Protection (-25~70°C) | Input Electrical | Low Voltage Protection | / | |
Over Voltage Protection | / | |||
Output Electrical | Shorted Circuit Protection | Hiccup, Auto Recovery. | ||
No-load Protection | Constant Voltage. | |||
Over Temperature Protection | / | |||
Environmental Requirement | Vibration | 10~25Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z, axes. | ||
Impact | 20G/11mS pulse,3times at each X, Y, Z axes. | |||
Storage Temp. & Hum. | -20°C~70°C; 10%~90%RH No condensing. | |||
Operating amb. Temp. & Hum. | -10°C~50°C; 20%~90%RH No condensing. | |||
Altitude | 3000m | |||
IPX | / | |||
Dielectric Strength (Hi-Pot) | Isolation Resistance | Input--out: 50M OHMS. | ||
Withstand Voltage | Input--out: 3KVAC/5Ma. | |||
Ground Impedance | / | |||
Other | Dimensions (L * W * H) | 100mm X 40mm X 25mm;±1mm | ||
Weight | 110g;±5g | |||
Package | / | |||
Cooling Method | Ventilation Cooling. | |||
Reliability | Burn-in | The power supply shall go a minimum of 4 Hours burn-in test under full load condition. | ||
Design MTBF | 50,000Hrs @25°C, MIL-HDBK-217 Method 2 Components Stress Method | |||
Design electrolytic capacitor life | 17520Hrs @50°C Full load and units continuously working. | |||
Note | Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. Test spare parts: test voltage for 500 VDC, 65% RH @ 25 °C. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. | |||
Minimum Negative Load Requirements | None | |||
Accessories | / |