HS Series Compact Single 200W 5V 40A Switching Power Supply (HS-200W)
Compact single switching power supply 200W
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Year warranty
Model | HS-200-5 | HS-200-12 | HS-200-15 | HS-200-24 | |
Output | DC voltage | 5V | 12V | 15V | 24V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | |
Rated current | 40A | 16.6A | 13.3A | 8.3A | |
Current range | 0~40A | 0~16.6A | 0~13.3A | 0~8.3A | |
Rated power | 200W | 199.2W | 199.5W | 199.2W | |
Ripple&noise(max.) | 150mvp-p | 180mvp-p | 180mvp-p | 200mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | |
Input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | |||
Frequency | 47~63Hz | ||||
AC current(Typ.) | 4.5A/115VAC, 2.5A/230VAC | ||||
Efficiency(Typ.) | 80% | 83% | 83% | 85% | |
Inrush current | cold start 18A/115VAC, 36A/230VAC | ||||
Leakage current | < 3.5mA/240VAC | ||||
Protection | Overload | above 115%~150% rated power | |||
protection type: shutoff O/P,auto-recovery after fault condition is removed | |||||
Environment | Working temp,humidity | -10°C~+60°C, 20%~90%RH | |||
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing | ||||
Withstand vibration | 10~500Hz,2G 10min/1cycle,period for 60 minutes,each axes | ||||
Safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | ||||
Fitstandard | Safety standard | Fit UL1012 | |||
EMC standard | meet EN55022, CLASS A | ||||
Others | Dimension | 199*110*50mm (L*W*H) | |||
Weight/packing | 0.85kg/24pcs/21kg/0.043 m³/1.51CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||