1500W Single Output Power Supply RSP-1500 series
Features:
* ZVS new technology
* High efficiency up to 91%
* AC input active surge current limiting
* Built-in active PFC function, PF>0.95
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Output voltage can be trimmed between 20 ~ 110% of the rated output voltage
* Forced air cooling by built-in DC fan
* High power density 8.3W/inch3
* Output voltage can be trimmed between 70~100% of the rated output voltage
* Current sharing up to 6000W(3+1)
* Alarm signal output
* Built-in 12V/0.1A auxiliary output for remote control
* Built-in remote ON-OFF control
* Built-in remote sense function
* 5 years warranty
Specifications:
MODEL | RSP-1500-5 | RSP-1500-12 | RSP-1500-15 | RSP-1500-24 | RSP-1500-27 | RSP-1500-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
CURRENT RANGE | 0 ~ 240A | 0 ~ 125A | 0~ 100A | 0 ~ 63A | 0 ~56A | 0 ~ 32A | |
RATED CURRENT | 240A | 125A | 100A | 63A | 56A | 32A | |
RATED POWER | 1200W | 1500W | 1500W | 1512W | 1512W | 1536W | |
RIPPLE & NOISE | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5~5.5V | 10~13.5V | 13.5~16.5V | 20~26.4V | 24~30V | 43~56V | |
VOLTAGE TOLERANCE | 2.0% | 1.0% | |||||
LINE REGULATION | 0.5% | ||||||
LOAD REGULATION | 2.0% | 0.5% | |||||
SETUP, RISE TIME | 1500ms, 100ms at full load | ||||||
HOLD UP TIME | 10ms at full load | 14ms at full load | 16ms at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY | 47 ~ 63Hz | ||||||
POWER FACTOR | 0.95/230VAC 0.98115VAC at full load | ||||||
EFFICIENCY | 80% | 87% | 87% | 90% | 90% | 91% | |
AC CURRENT | 17A/115VAC 8/230VAC | ||||||
INRUSH CURRENT | 30115VAC 60230VAC | ||||||
LEAKAGE CURRENT | <2A / 240VAC | ||||||
PROTECTION | OVER LOAD | 105 ~ 135% output power | |||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 5.75~6.75V | 13.8~16.8V | 17~20.5V | 27.6~32.4V | 31~36.5V | 57.6~67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMP | 95oC 5 (RTH2 : detect on heatsink of power transistor) | ||||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |||||||
FUNCTION | AUXILIARY POWER | 12 @ 0.1A (Only for Remote ON/OFF control) | |||||
REMOTE CONTROL | Please see the Function manual | ||||||
ALARM SIGNAL OUTPUT | Please see the Function manual | ||||||
OUTPUT VOLTAGE TRIM | Please see the Function manual | ||||||
CURRENT SHARING | Please see the Function manual | ||||||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70oC(Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP HUMIDITY | -40 ~ +85oC , 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | 0.05/oC (0 ~ 50oC ) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY &EMC | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204,EN55024,ndustry level, criteria A | ||||||
OTHERS | MTBF | 62.6s min. MIL-HDBK-217F (25 ) | |||||
DIMENSION | 278*127*83.5MM (L*W*H | ||||||
PACKING | 2.6KG;6pcs/16.6kg/1.54CUFT |