Features:
Specifications:
MODEL | PLP-60-12 | PLP-60-24 | PLP-60-48 | |||
OUTPUT | DC VOLTAGE | 12V | 24V | 48V | ||
CONSTANT CURRENT | 9 ~ 12V | 18 ~ 24V | 36 ~ 48V | |||
CURRENT RANGE | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.3A | |||
RATED CURRENT | 5A | 2.5A | 1.3A | |||
RATED POWER | 60W | 60W | 62.5W | |||
RIPPLE & NOISE (max.) | 4.5Vp-p | 4.5Vp-p | 4.8Vp-p | |||
VOLTAGE ADJ.RANGE | 3.75 ~ 5A | 1.875 ~ 2.5A | 0.975 ~ 1.3A | |||
VOLTAGE TOLERANCE | 10% | |||||
LINE REGULATION | 3.0% | |||||
LOAD REGULATION | 5.0% | |||||
SETUP, RISE TIME | 1000ms / 230VAC 2000ms / 115VAC at full load | |||||
HOLD UP TIME (Typ.) |
| |||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR | PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC | |||||
EFFICIENCY (Typ.) | 84% | 88% | 89% | |||
AC CURRENT (Typ.) | 0.8A/115VAC 0.4A/230VAC | |||||
INRUSH CURRENT (Typ.) | 42A/230VAC | |||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||
PROTECTION | OVERCURRENT | 100 ~ 110% | ||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||
SHORT CIRCUIT | Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 15 ~ 18V | 28 ~ 33V | 57 ~ 63V | |||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE |
| |||||
| ||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70 (Refer to output load derating curve) | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||
STORAGE TEMP, HUMIDITY | -40 ~ +80 , 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50 ) | |||||
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | TUV EN61347-1, EN61347-2-13 approved ; design refer to UL60950-1 | ||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |||||
EMI | Compliance to EN55015 | |||||
HARMONIC CURRENT | Compliance to EN61000-3-2 Class C( 75% load); EN61000-3-3 | |||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A | |||||
OTHERS | MTBF | 583.3Khrs min. MIL-HDBK-217F (25 ) | ||||
DIMENSION | 101.6*50.8*29.6mm (L*W*H) | |||||
PACKING | 0.16Kg; 96pcs/16.4Kg/0.89CUFT |