Specifications:
MODEL | PLP-20-12 | PLP-20-18 | PLP-20-24 | PLP-20-36 | PLP-20-48 | |||||
OUTPUT | DC VOLTAGE | 12V | 18V | 24V | 36V | 48V | ||||
LED OPERATION VOLTAGE NOTE.5 | 9~12V | 13.5~18V | 18~24V | 27~36V | 36~48V | |||||
RATED CURRENT | 1.6A | 1.1A | 0.8A | 0.55A | 0.42A | |||||
RATED POWER | 0~1.6A | 0~1.1A | 0~0.8A | 0~0.55A | 0~0.42A | |||||
RIPPLE & NOISE (max.) Note.2 | 2.5Vp-p | 3.0Vp-p | 3.0Vp-p | 3.0Vp-p | 3.8Vp-p | |||||
CURRENT ADJ.RANGE | 75%~100% | |||||||||
VOLTAGE TOLERANCE Note.3 | 10% | |||||||||
LINE REGULATION | 3.0% | |||||||||
LOAD REGULATION | 10% | |||||||||
SETUP, RISE TIME | 2300ms, 200ms / 230VAC 3000ms,200ms/115VAC at full load | |||||||||
INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127 ~ 392VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR | PF>0.9/230VAC | |||||||||
EFFICIENCY (Typ.) | 80% | 81% | 82% | 83% | 83.5% | |||||
AC CURRENT (Typ.) | 0.4A/115VAC 0.2A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | 40A/230VAC | |||||||||
LEAKAGE CURRENT | 0.5Ma/240VAC | |||||||||
PROTECTION | OVERCURRENT | 95 ~ 110% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode,recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 14~16V | 19~22V | 27~34V | 41~46V | 54~60V | |||||
Protection type : Shut off o/p voltage,clamping by zener diode | ||||||||||
OVER TEMPERATURE | 110Oc 10Oc(TSW1) | |||||||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||
ENVIRONMENT | WORKING TEMP. | -30~ +60 oC(Refer to output load derating curve) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80 , 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | 0.06%/ oC(0 ~ 50 ) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | TUV EN61347-1,EN61347-2-13,UL8750 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms/500VDC/25 / 70%RH | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55015 | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,CLASS C( 75% load),EN61000-3-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level, criteria A | |||||||||
OTHERS | MTBF | 643.6Khrs min. MIL-HDBK-217F (25 ) | ||||||||
DIMENSION | 140*32*22mm (L*W*H) | |||||||||
PACKING | 0.12Kg; 60pcs/9.2Kg/0.62 CUFT |