Product Description
240w Specifications sheet | ||||||||
model | S-240-5 | S-240-7.5 | S-240-12 | s-240-13.5 | S-240-15 | S-240-24 | S-240-27 | S-240-48 |
DC Output voltage | 5V | 7.5V | 7.5V | 13.5V | 15V | 24V | 27V | 48V |
Output voltage range(Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 45A | 33A | 20A | 18A | 16.5A | 10A | 9A | 5A |
Output current range | 0~45A | 0~33A | 0~20A | 0~18A | 0~16.5A | 0~10A | 0~9A | 0~5A |
Wave and noise(Note:3) | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 225W | 240W | 240W | 240W | 240W | 240W | 240W | 240W |
Efficiency | 74% | 79% | 83% | 83% | 84% | 85% | 85% | 86% |
Adjustable range | 4.5~5.6V | 6~9V | 10~13.2V | 12~15V | 13.5~18V | 20~26.4V | 26~32V | 41~56V |
AC input voltage range | 90~132VAC/180~264VAC selected by switch 47~63Hz, 254~370VDC | |||||||
Input current | 3.6A/115V 1.8A/230V | |||||||
AC Inrush current | 25A/115V 50A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Overload protection | 105 ~ 150% Type: pulsing hiccup shutdown Reset: auto recovery. | |||||||
Over-voltage protection | 115%~135% | |||||||
Temperature coefficient | ±0.03%/°C(0~50°C) | |||||||
Setup, rise, hold up time | 200ms, 100ms, 20ms | |||||||
Vibration | 10~500Hz, 2G 10min,/1 cycle. Period for 60min, Each axes | |||||||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||
Working temperature and humidity | -10°C~+60°C (Refer to output derating curve), 20%~90%RH | |||||||
Store temperature and humidity | -20°C~+85°C, 10%~95%RH | |||||||
dimension | 199X110X50mm (L*W*H) | |||||||
Weight | 0.82Kg | |||||||
Safety standards | Design refer to UL 1950 | |||||||
EMC standards | Design refer to FCC PART15J class A | |||||||
Note: | ||||||||
1. The parameter under the testing condition : 230VAC input, rated load, 25°C70% RH. Temperature. | ||||||||
2. Tolerance: Including setting tolerance, circuit stability and load stability. (Note: 5). | ||||||||
3. Wave test: Adopting “A12” double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting. | ||||||||
4. Inlet voltage stability test: the lowest voltage will be up to the highest voltage when the circuit overload. | ||||||||
5. Load stability test: The load is from 0% to 100%. | ||||||||
6. C3, 4, 32 must be knocked down. |