Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Brand Name DRAWELL
Place of Origin Shanghai, China
Model Number DW-AA4530F
Size 70x55x45cm (Main instrument)
Weight 75kg
Wavelength Range 190-900nm
Focal Length ≤0.5nm, 0.1, 0.2, 0.4, 1.0 and 2.0nm

Product Features

Atomic Absorption Spectrophotometer

Model: DW-AA4530F

 

 

CHARACTERISTICS:

1. Completely controlled by PC, canflexibly select the flame and graphite furnace atomizer (optional).

2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize

the working condition of thehollow cathode lamp.

4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.

5. Fully automated wavelength scanning and peak searching.

6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.

7. Deuterium lamp and self-absorption background regulation.

8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method andthe result can be randomly called.

9. Measuring method: flame absorption method and emission method.

10.Result printing: parameter printing, data result printing and diagram printing.

 

COMPLETE AUTOMATIC CONTROLLING SYSTEM:

With the help of the software, the following can be easily achieved

1. Selection of the element lamp

2. Up-down-front-rear adjustment of thelifter

3. Adjustment of the optical energy

4. Selection of the slit

5. Determination of wavelength scanning and peak searching

6.  Selection of the atomizer

7. Setting of the background deduction method

8.  Controlling of the gas flow

9. Automatic flaming and flaming out

10.Setting of the graphite furnace testing method

 

ADVANCED GRAPHITE FURNACE TEMPERA-TURE CONTROLLING TECHNOLOGY:

The bringing in of PID technology can effectively overcome the influence on thetemperature rising process caused by the voltage fluctuation andthe resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data

The fast heating capacity can improve the flexibility of the elements further

Use the ordinary power source of 220V without needof dynamic power of 380V

The maximum procedure heating capacity setting of20 levels can make a more convenient and easier testof different samples

Three grades adjustable gas flow can accustom to moreapplication needs

Can  timely  alarm  when  the  gas  and  water  is

stopped and insufficient gas and water, can avoid the equipment damage and measuring error

 

SAFE,  RELIABLE AND  CONVENIENT FLAME SYSTEM:

EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily Efficient

atomization system enables a higher sensitivity

The whole operation system has a high security as the fire safety system can alarm whenever the electrici- ty is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit temper ing. Thus itkeeps the operation people and equipment from harm and damage.

 

MULTI-FUNCTIONAL SOFTWARE WORKSTATION:

A w o r k s t a t i o n t h a t i s s u p p o r t e d W I N D OW S XP/20 00/NT

The rich menu brings great convenience to the use ofcustomer

Convenient conversion between different menus makes the operation more easily

Various analytical correction methods provide the

users more choices

Basic default parameter settings enable even the beginners can do the normal operation

Flexible sto r age, e ditin g and p rin tin g m e th ods give the user largest support

 

Specifications

Wavelength range

190 – 900nm

Spectral bandwidth

0.1, 0.2, 0.4, 1.0 and 2.0nm

Accuracy of the wavelength

±0.15nm

Receptivity of the wavelength

≤0.04nm

Base line stability

≤0.002A/30min (Cu)

Characteristic viscosity

0.02μg/ml/1% (Cu)

Checking limit

0.004μg/ml (Cu)

Preciseness

0.5%

Grating               

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Effective glass atomizer

Lamp stand     

8

 

Flame System

Acetylene air burner 

 100mm

Ignition dynamic baseline drift

≤0.006A/30min

(Cu) Characteristic viscosity

≤0.025μg/ml/1%

Related standard deviation of the accuracy 

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety system    

 

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

 

Graphnite Furnace

The highest temperature

3000℃

The largest temperature rising speed   

 ≥2000℃/S

Characteristic quantity

 Cd≤0.5×10-12g  Cu≤0.5×10-11g

Accuracy

Cu≤3% Cd≤3%

Safety system

Over current protection Low air pressure alarm /protection Low cooling water flow alarm/protection

Power source and power

220V±22V  AC  7000W

 

STANDARD ACCESSORIES

PC workstation

HP ink-jet printer

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Air filter

 Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530FFlame AAS Atomic Absorption Spectrophotometer DW-AA4530FFlame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530FFlame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F

 

products display

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F 

company profile

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F 

contacts us

Flame AAS Atomic Absorption Spectrophotometer DW-AA4530FFlame AAS Atomic Absorption Spectrophotometer DW-AA4530F 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now