Specifications
1. True ECG Waveforms2. Most functional, can generate many kinds of waveforms
2. LED display
3. Lithium Battery
SKX-2000G ECG signal simulator
This SKX-2000G ECG signal simulator can provide simulation of ECG and respiratory signal and can be used for testing, inspection and maintenance ECG machine and monitor. It is a powerful tool for the majority of production and maintenance personnel in medical equipments.
The simulator can produce the following waveform, the following code represents a waveform.
1.Normal ECG waveform
2.The positive and negative triangular waveform
3.Analog triangle waveform, irregular heart beats
4.Square wave, square wave measurement scanning speed
5.The sine wave, measuring the amplitude and frequency characteristics
6.Analog breathing waveform
7.Simulation fetal heartbeat (Another optional tooling)
8.Set the amplitude of the signal
9.With the ECG signal from the Pacing signal
10.Can change the width of the bottom of the triangular wave
11.Can change the amplitude of the T wave, heart rate, QRS wave amplitude and width of the QRS Wave of ECG waveform
12. Pacing signal
13. Superimposed 2Hz sine waveform of the triangular wave
Note:
1: after power on the simulator automatically generates the waveform normal ECG waveform.
2: Simulator LED display tube, in order to prevent the user forget to turn off the power, the system in the course of design when the operation buttons within 24 hours, the CPU will enter standby mode, so that energy-saving, boot will work properly again. Press any key time zero.
3: the the ECG connection: RA-R (right hand), La-L (left hand), LL-F (left leg), The RL-RF (right leg), a C1-C6 chest lead
4: Monitor connection: RA-right hand (white), LA-left hand (black), LL-left foot (red), RL-foot (green), C1-C6 chest leads (brown)
5: three lead connection method: RA-right hand (white), LA-left hand (black), LL-left foot (red)
6: corresponding to European standard connection: L-LA R-RA RF (N)-RL F-LL CV
Description about Keys
There are four buttons, turn the selection key, key, lower key, Enter key, in addition to a set of
key combinations
Select key:
This button is used to select the parameters you want to change, and a total of four LED tubes
to display 4 code, respectively, represent the contents of the display,
1, for waveforms code, 2-4 delegates representing the waveform code you want to change the
parameters of (2 is the value of one hundred, 3 represents ten 4 represents a bit)
LED tube of the highlights of the lower-right corner, indicating the contents of the currently
selected; can be changed.
Increase key:
When using the Select button to select change, use this key parameter changes.
Decrease key:
When using the Select button to select good change, use this key parameter changes.
Enter key:
Parameter changes after this key confirmation will confirm the parameter changes and
corresponding waveform.
Key combinations:
Press the Select key, and then press the Enter key, the Enter key is released, release the Select
button, and then choose a key combination, press the Enter key again will display different
content.