Outline and size
Instrument type | length | width | height |
AKHC-EKA | 60 | 64 | 16 |
Attention:
1. When the hall sensor is used, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary side coil and the secondary side coil. It is recommended to use a single wire and the wire completely fills the hall sensor module wire hole;
2. When the hall sensor is used, the best measurement accuracy can be obtained under the rated input current value. When the measured current is far lower than the rated current To obtain the best accuracy, multiple turns can be used for the primary side, i.e. IPNP = rated ampere turns. In addition, the temperature of the primary side feeder shall not exceed 80 ℃;
3. The auxiliary power supply of Hall current sensor shall not exceed ± 20% of the calibrated value when it works normally;
4. Hall current sensor shall not fall from a high place (≥ 1m) during installation and use;
5. It is unable to adjust the zero point and full degree adjustment potentiometer;
6. Auxiliary power supply needs to be configured by itself;
7. The positive and negative poles of the power supply cannot be reversed.
You May Like
- Acrel AHKC-EKB uninterruptible power supplies 0-200-1000A signal isolator transmitter hall sensor
- Acrel AHKC-EKB battery supplied applications 0-200-1000A signal isolator transmitter hall sensor
- Acrel AHKC-EKB AC variable speed drives 0-200-1000A signal isolator transmitter hall sensor
- Acrel AHKC-EKB 1 class accuracy 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB extended measuring range 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB low power consumption 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB small package size 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB AC,DC,pulse and other complex current signals measuring 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB uninterruptible power supplies 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB battery supplied applications 0-200-1000A current sensor hall sensor
Popular Searches
Find Similar Products By Category
You May Like
- Acrel AHKC-EKB AC variable speed drives 0-200-1000A current sensor hall sensor
- Acrel AHKC-EKB 1 class accuracy 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB extended measuring range 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB low power consumption 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB small package size 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB AC,DC,pulse and other complex current signals measuring 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB uninterruptible power supplies 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB battery supplied applications 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB AC variable speed drives 0-200-1000A current transducer measurement hall sensor
- Acrel AHKC-EKB 1 class accuracy 0-200-1000A split core current transmitter hall sensor
- Acrel AHKC-EKB extended measuring range 0-200-1000A split core current transmitter hall sensor
- Acrel AHKC-EKB low power consumption 0-200-1000A split core current transmitter hall sensor
- Open loop dismountable hall effect current sensor DC current hall sensor input 0-500A output DC4-20mA
- Hall effect flow sensor AC current transformer Voltage sensor input AC0-50A output DC4-20mA
- Hall current sensor/transducer Acrel AHKC-EKDA AC current sensor AC0-50A open loop transmitter