APPLICATION
· Fluid Level Measurement of Tank of Petrifaction, Pharmacy, Food Process
· Water Level Control and monitor of Water conservancy
Outputs: Digital— Modbus,
Analog—voltage, current
SPECIFICATION
Measured position: Modbus—1~3 position or 1~5temperature
Analog—1~2 position
Range: 50~76000mm
Input power: 24V
Communication: EIA-RS485
Update time: SSI, Modbus: length 1200 2400 4800 7000
Time 0.5 1.0 2.0 5.0 ms
Operating temperature: -40° to +85° C
Storage temperature: -40° to +100° C
Probe: depends on floats
Insulation: 500VDC
Performance Parameter
Nonlinearity: ±0.05%F.S.(max)
Repeatability: ±0.002%F.S.(max)
Hysteresis: Modbus: 4μm(max)
Analog: 0.002%F.S.(max)
Resolution: Modbus: 4μm(max)
Analog: 16bit D/A output
Temperature coefficient: ±0.007%F.S./ ° C
System resolution: Modbus: 4μm(max)
Analog: depends on indicated controller
Accuracy of temperature measurement: ±0.5° C
Zero range: 100%F.S.
Physical Specifications
Probe: 304SS wetted parts or 316SS
Cover: Anodized aluminum(standard), 304SS(flame-proof type)
Mounting: threaded flange
Flange standard: GB9115.1-2000
Cable: integral cable, high temperature resistant cable, mating connector, integral connector
Environmental Protection: IP65
Explosion Proof: ExdIIBT5 (Flameproof), ExiaIIBT5 (Intrinsic safety)