1 overview

The DF300 is one kind of high resolution capacitance level sensor, the resolution is 0.1%FS or 1mm (the bigger value). It is made of stainless steel 304 (optional for 316). It is robust for vibration, such as vehicle, generator, railway train and etc.  Also it is good for bad quality liquid, such as sewage or other water.

It is applicable for the close container or open container or pool or river.   As with RS485, it is easy to integrate into the embedded system or SCADA.

In order to realize remote monitoring, there are wireless module optional for DF300, including zigbee, Wifi, GPRS, 3G. Furthermore, GPS module is one optional for the DF300. As a result, DF300 can be used as gps tracker also.

2specifications

 

Length10-1000mm
Resolution0.01mm
Pressure-0.1MPa~0.1MPa
Sensor diameter16mm
OutputAnalog Voltage:0-5V , or Digital: RS 232/485
VoltageDC 12~40V
Explosion-proofEXia II C T6
MountingFlange
MediaDiesel

 

3 applications
F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output
 F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

Mechanical Drawing

F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

5System Diagram

F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 6Test Report

6.1 Device

F300,  cylinder container, computer

 

6.2 Data

 

Round I

Round II

Difference of Two Test

 

Batch

S/N

Unit(0.1%)

Old Design

140317

140317089

 

451

 

140317102

421

 

 

140317127

420

444

24

New Design

150306

150306009

417

444

27

150306035

 

452

 

150424

150424005

392

417

25

150424010

409

439

30

150424015

401

426

25

Max

421

452

31

Min

392

417

25

Mean

410

439

29

Variation

29

35

 

 

6.3 Conclusion

Variation for different batch <=3.5%

7 Installation & Cases

 

7.1 Installation

F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output 

Before the installation, please check sensor and accessory,such as rubber blanket,screws and tools for drilling hole.

If your tank have a old probe sensor ,you need to remove ,then put the new sensor on your tank . Otherwise,you can directly go to next step.  

Drill big hole on the tank according to the following diagram,  diameter is 30-40mm. Then put the flange on the big hole, and position the small screw, then drill small hole for screw.

 

F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog outputF300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output   

Put the glue on the rubber blanket ,then put it under the flange

Put the sensor in the tank at first ,screw to fix it

Connect the power line and signal line according to the definition

Notes: Mounting Position of the sensor should be close to the center of the tank, which can reduce the oil level slope and oil level wave when the vehicles are uphill and downhill.

The sensor is automatically calibrated, so no need to do special calibration.

Put the glue on the rubber blanket ,then put it under the flange

Put the sensor in the tank at first ,screw to fix it

Connect the power line and signal line according to the definition

8 Protocol (for RS232/485/wireless version)

The default baud rate is 9600bps, one start bit, eight data bit, one stop bit, no checksum bit.

8.1 Read Level AD Value

Request: From device to sensor.

ASCII: $!RY0151

Hex: 24  21  52 59 30  31  35  31  0D 0A

$! is header, RY is command, 01 is sensor id, 51 is end.

 

Reply: From sensor to device

ASCII: *CFV0100FA32B6 

Hex: 2A  43  46  56  30  31  30  30  46 41  33  32  42 36  0D  0A 

* is header, CFV is reply command. 01 is sensor id. 00FA32 is AD value for level. 00 is the padding to fulfill 6 bytes of data section required. FA32 is the level AD value.  Level 0%~100%  equals with 000000~00FFFF.

8.2 Read Level Percent

Request: From device to sensor.

ASCII: $!DO0139 

Hex: 24  21 44  4F  30  31  33  39  0D 0A

$! is header, DO is command, 01 is sensor id, 39 is end.

 

Reply: From sensor to device

ASCII: *RFV01000.0198 

Hex: 2A  52 46 56  30  31  30  30  30 2E   30 31 39 38  0D  0A

* is header, RFV is reply command. 01 is sensor id.  000.01 is the level value in percent. Max is 100.00.

8.3 Set Sensor ID

Request: From device to sensor.

ASCII: $!ID0133 

Hex: 24  21 49 44  30  31  33  33  0D 0A

$! is header, ID is command, 01 is sensor id, 33 is end.

 

Reply: From sensor to device

ASCII: *SID01OKOKOK39  or *SID01NONONO42 

Hex: 2A  53  49 44 30  31  4F   4B  4F  4B  4F   4B 33  39  0D  0A 

or 2A  53  49 44 30  31  4E   4F  4E  4F   4E   4F   34  32  0D  0A

* is header, SID is reply command. 01 is sensor id.  OKOKOK means succeed. NONONO means failed.

 8.4 Set damping parameter 

Request: from computer to sensor


ASCII     :   $!Z40134  

Z  is command,01 is ID of sensor,

4 is damping sensor, the range is 1,2,3,4,5,6, .  1 is the smallest parameter, in this condition, the value will update quickest. 6 is the biggest value, in this condition, the fluctuation will be filtered mostly.

In hex   :   24  21  5A  34  30  31  33  34  0D 0A 

 

Reply: fro sensor  to computer

ASCII     :   *SZN01OKOKOK54   is ok reply

                 *SZN01NONONO5D  is fail reply

In hex     :   2A 53 5A  4E   30  31  4F  4B  4F   4B 4F   4B  35 34 0D 0A 

                 2A  53 5A  4E   30  31  4E   4F   4E   4F   4E  4F   35 44  0D  0A

Notes: The protocol maybe update without notification. Please contact with us for the latest protocol.

9.1 Naming Rules

 F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

 

 

9.2 Length Clarification

 

 F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

 

Packaging & Shipping

 

Standard export packingF300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

 

Our Services

 

Warranty

We warrants this quality product to be free of defects in material and workmanship for a period of 12 months from the date of purchase. During the period, we will repair or replace the product at no charge for partsor labor. But the shipment fee will be shared by the buyer (one party 50%). 

The time period of this warranty starts from the date of the original purchase and expires on the first anniversary date of purchase.

F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 

 

Company Information

 F300 capacitance type level sensor fuel level sensor for truck applicabled for fuel gasoline water ethanol analog output

 If you interested in our products,please contact us:

  

Looking forward to cooperating with you

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now