Product Details

1000VA 2000VA 3000VA 6000VA pure sine wave rack mount online ups USB , RS232 Interface for telecom

Brand Name Jendia/OEM
Place of Origin China
Model Number rack mount ups 3kva

Product Features

Delivery Time:15-20days
Certification:CE,ISO9001

1000VA 2000VA 3000VA 6000VA pure sine wave rack mount online ups USB , RS232 Interface for telecom   Specifications 1.double conversion
2.wide input voltage,zero transfer time
3.RS232 interface
4.advanced IGBT
5.pure sine wave online ups

1000VA 2000VA 3000VA 6000VA pure sine wave rack mount online ups for telecom

Product Feature:

1,True on-line double conversion technology with advanced microprocessor control;
2,Wide input voltage range;
3,Zero transfer time;
4,Protection against all type of power problems;
5,Self test while start of the UPS;
6,Site wiring fault warning;
7,On-battery power-on function;
8,Smart RS232 communication interface;
8,Intelligent slot available;
10,Sealed lead-acid, maintenance free battery.

Typical Application


Servers, Data centers, Critical network devices, Sensitive electronic equipment, Telecom.

Technical Specidication

High Frequency Online UPS Rack Mount Series UPS RT1000/2000/3000/6000VA Specifications

Product Series Rack Mount 1KV~6kVA
Model RT1KR RT2KR RT3KR RT6KR
RatedPower VA/W 1KVA
/400W
2kVA
/1400W
3kVA
/2100W
6kVA
/4200W
Nominal Voltage 220V / 230V / 240V/AC
Voltage Range 115 ~ 300VAC 176 ~ 276VAC
Frequency Range 46 ~ 54Hz(default),user adjustable within 40~60Hz 46 ~ 54Hz
Power Factor 0.97 0.98
Connection IEC 320-10A inlet IEC 320-16A inlet Terminal Block
Voltage 220VAC ± 2% 220VAC ± 1%
Frequency 46~54Hz or 50Hz ± 0.2Hz(Line mode)
50Hz ± 0.2Hz( Battery mode)
46~54H(Line mode)
50Hz ± 0.05Hz(Battery mode)
Waveform Pure Sine Wave
Overload Capability 108%~150% for 30 sec.,
³150% for 300 ms
105~130% for 10 min.,
³130% for 1 min.
Current Crest Ratio 3:1
Output
Bypass Automatic Transfer on overload and UPS failure
Before UPS
Power-on
Default \"NO\",
user adjustable to \"YES\"
Yes
Voltage
Range 
80~264VAC (Default),
user adjustable within 80~286VAC
176 ~ 261VAC
Output
Connections
IEC
320 -10A * 4
IEC 320-10A * 4 IEC
320-10A
and
Terminal
Block
IEC
320-10A * 4 
and Terminal Block
Transfer Time 0 ms; less than 4 ms from inverter
to bypass and vice versa
Zero
LED/LCD
Indicators
Load level / Battery level, Battery ,
Utility Power, Inverter, Bypass,Overload, Fault
Audible Alarm Bypass, On battery mode,
Battery low, Overload, Fault
Communications RS-232 Serial Interface

Intellig

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now