Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ OVERVIEW ♠♠♠♠
Overview about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
ISG model vertical oil centrifugal pump is single-stage end-suction(axial suction) cantilever type centrifugal pump, which is used to transport corrosive liquid with viscosity similar to water and without solid particles. The marked and rated performances and dimensions adopt international standard.
♠♠♠♠ FEATURE ♠♠♠♠
Features about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
1. Centrifugalvertical boiler feed water pump is a high-effective energy-saving, easily dismantled product designed by Ronda.
2. It is used to transport the liquids containing no solid grain, corrosive and the viscosity of which is similar to oil.
3. Pump is with the merits of compact structure, small volume, stable running, easy to mount and maintain.
4. Widely used in light&textile industry, petroleum, chemical industry, metallurgical industry, mining, medicine and synthetic fiber etc.
5. ISG vertical oil pump is based on ISG vertical inline pump. This pump has very wide range specifications. YGB is with departed shaft structure, which is easy to dismantle .
♠♠♠♠ APPLICATION ♠♠♠♠
Application for Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
The vertical oil centrifugal pump apply to transport liquid whose impurity content is lower than 1% and the max particle size is smaller than 0.1mm, or whose chemical and physical characteristics is similar to clean water.
They are always used on daily-use and fire-emergence water for tall buildings. And they also can be used to supply water in mine, cities towns, companies and low pressure boiler.
♠♠♠♠ MODELS ♠♠♠♠
Models of Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
ISG: Direct Vertical Inline Pipeline Booster Boiler Feed Water Pump
♠♠♠♠ TEPERATURE ♠♠♠♠
TMPERATURE about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
Up to 80Celsius Degree
The temperature of transported media of ISG model High pressure vertical pipeline vertical oil centrifugal pump , vertical inline pump is -20 to 105 C deg . Through adopting cooling method, it can transport media with higher temperature if necessary, and is applied to transport various corrosive media or media in which pollution is forbidden similar to water in such industries as chemical industry, petroleum, metallurgy , electric power, papermaking, food, pharmacy and synthetic fiber etc.
♠♠♠♠ ADVANTAGES ♠♠♠♠
Advantages about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
It has such characteristics as wide range of performance, high efficiency, high mechanical, chemical and physical level and convenient maintenance etc. It is energy saving type product recommended by the nation with its efficiency being 5% greater than that of other similar model pump.
♠♠♠♠ PERFORMANCE ♠♠♠♠
Performance for Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
Type | Flow (m3/h) | Head (m) | Power (KW) |
ISG50 | 3.4-15 | 3.7-68.8 | 0.55-11 |
ISG65 | 6.8-30 | 3.7-126.8 | 0.55-30 |
ISG80 | 13.6-60 | 3.6-128 | 0.55-45 |
ISG100 | 27.3-120 | 3.4-115.5 | 1.5-75 |
ISG125 | 56-240 | 8.5-132.5 | 2.2-110 |
ISG150 | 99-240 | 12.4-57.5 | 15-55 |
ISG200 | 197.7-460 | 14.8-55.8 | 30-90 |
♠♠♠♠ CONSTRUCTION ♠♠♠♠
Constructions about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ DIMENSIONAL DRAWING ♠♠♠♠
Dimensional drawing about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ FAQ ♠♠♠♠
Tips for Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
Please take note as below when install the pump:
1. The preformed hole on the foundation should be poured as the pump installation drawing.
2. The installation level should meet the demand of the allowed vacuum suction height. The foundation should be in horizontal and stable condition, to make sure the rotation of the driver machinery same with the pump in the direction.
3. When connect by coupling, must make sure the pump and driver shaft center should be in a straight line.
4. If belt connection, the shaft center should be in parallel.
5. The vertical oil centrifugal pump suction pipe should be sealed well, and try to less the quantity of the elbow and check valve. When fill water, exhausted the air. It should be no any air when operate. We need to keep the suction pipe slopes up slightly, and then connect with the pump inlet.
♠♠♠♠ INSTALLATION ♠♠♠♠
Installation about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ PACKAGING & SHIPPING ♠♠♠♠
Pakcaging and shipping about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ ABOUT US ♠♠♠♠
♠♠♠♠ CERTIFICATION ♠♠♠♠
Certification about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
♠♠♠♠ CONTACT ♠♠♠♠
Contact AN PUMP about Booster Circulation Direct Closed Coupled Vertical Inline Pipeline Circulation Booster Water Pump
Ailen