Product Details

SRMD 4-20mA diaphragm pressure transmitter with Hart

Place of Origin Shandong, China
Brand Name Dongrun
Model Number SRMD

Product Features

Company Introduction                                        

Yantai dongrun Instrument Co., Ltd. was founded in 1998, specializes in manufacturing online water quality analysis equipment, material level meters, pressure gauges, flow metersspecial temperature gauges and laboratory analysis equipment. Our company cooperate with the Chinese Academy of Sciences to build a water analysis laboratory, and the main products are TOC analyzer, ammonia analyzer, fluorescence oxygen analyzer, etc. We have passed the ISO9001 certification and has a professional R & D team, providing technical support to meet customer demand, particularly in the anti-corrosion, our company has a unique technology to meet different conditions of corrosion requirements. 

 Product Introduction                                      

 

SRMD Intelligent Capacitive Pressure/Differential Pressure Transmitter 

Product Introduction

 Series SRMD digital pressure / differential pressure transmitter is based on the advanced, mature, reliable capacitive sensor technology in the world and combines the advanced monolithic computer technology and the digital conversion technology of the sensor.

 

 The core component adopts a 16-bit micro controller. Its powerful features and high-speed computing power ensure the good quality of the transmitter. The entire design framework focuses on reliability, stability, high precision and intelligent to meet the increased requirements of the industrial field applications. The digital signal processing technology is applied in the software, which makes it have excellent anti-interference ability and zero stability as well as zero automatic stable tracking capabilities (ZSC) and temperature automatic compensation capacity (TSC).

 

 

Performance Index

 

Performance specifications
(Reference conditions: no migration status, silicone oil filling fluid, 316L isolation diaphragm)
Output signal: 4 ~ 20 mA DC.
Transmission forms: two-wire 

 

Accuracy:

 

Linear output:  ± 0.1% (range ratio 1:1), including linear, variation, repetitive comprehensive errors.

 

Sqrt output: when the output pressure is 4 to 100%, it is ± (0.2% calibrated span     +0.05% upper limit).

 

Stability: For DP range code 3, 4, 5, it is ± 0.2%of a maximum range. For the rest of the range code, it is ± 0.25% of the maximum range.

 

Humidity: 0 to 90% relative humidity

 

Start time: minimum damping, 2 seconds at most

 

Volume uptake: less than 0.16cm3.

 

Damping: The electrical damping is 0 to 32 seconds.

 

Furthermore, the sensitive element has constant damping time of 0.2s (The measurement range code 3 is 0.4 seconds).

 

Static pressure influence: (DP transmitter)

 

Zero error: For 14Mpa, it is ± 0.25% of the maximum range. For the range code 3, it is ± 0.5% of the maximum range. It can be corrected by the zero adjustment.
Measurement range Error: every 6MPa can be corrected to ± 0.25% of the input indication. For the range code 3,it is ± 0.5%. This error can be adjusted to eliminate before installation.
Static pressure (HP transmitter)
Zero error: For the 32Mpa, it is ± 1.0% of the maximum range. Through the zero point adjustment, it can be corrected.
Temperature
Zero error in the maximum range
Every 56 ℃ is ± 0.5% of the range. The total impact includes the range and zero error:  every 56 ℃ is ± 1.0% of the range. For range code 3, the amount of impact is doubled.
Zero error in the minimum range: every 56 ℃ is ± 3% of the range.
The total impact includes range and zero error. Every 56 is ± 3.5% of the range. For range code 3, the amount of impact is doubled.
 vibration influence: frequency :0 ~ 200Hz, every g is ± 0.05% upper limit in every direction.
Power influence: less than 0.005% / Vof the calibration range.
Installation location influence: Zero drift is not larger than 0.25kPa. This error can be eliminated by correction with no effect on the range.
 electromagnetic interference / radio frequency interference influence: In accordance with the SAMA PMC33.1, test is conducted from 20 ~ 1000MHZ. The field strength can be as high as 30V / m.

SRMD 4-20mA diaphragm pressure transmitter with HartSRMD 4-20mA diaphragm pressure transmitter with Hart

 

SRMD 4-20mA diaphragm pressure transmitter with Hart

Company and Trading show 

 

 

SRMD 4-20mA diaphragm pressure transmitter with HartSRMD 4-20mA diaphragm pressure transmitter with Hart

Shipping charge 

SRMD 4-20mA diaphragm pressure transmitter with Hart

 

edith sun 

skype: dongrun01

ph:  13793523708

 

 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now