Product Details

Automation System 14DI / 10DO Relay PLC Logic Controller RS232 to RS485

Brand Name UniMAT
Place of Origin China
Model Number UN 214-1BD23-0XB0

Product Features

Delivery Time:As soon as payment confirmed
Certification:CE

UniMAT CPU 14DI / 10DO Programming Logic Controller Compatible With Siemens PLC

Quick description :

1). 14DI, 10 DO with relay

2). Communication Ports: 2RS - 485, both support PPI protocol ; 

3). Supports expansion modules : 7 modules ;

4). Compatible with Siemens 224 CPU ;

5)). 3- year warranty ;

6). Siemens software is ok.

Detail description :

Technical specifications
Model CPU224 AC/DC/Relay
Physical characteristic
Dimensions(W x H x D)(mm) 120.5×80×62
Power consume 10W
Memory   
Program memory size  
With run mode edit 20K bytes
Without run mode edit 20K bytes
Data memory 10K
I/O  
Local digital inputs 14 inputs
Local digital outputs 10 outputs
Digital I/O image size 256(128 inputs /128 outputs)
Analog I/O image size 64(32 inputs / 32 outputs)
expansion modules allowed (Max) 7 modules
intelligent modules allowed (Max) 7 modules
Pulse catch inputs 14
High-speed counters 6 counters total
Single phase 6 at 30KHz
General  
Timer Total number: 256 (1ms:4;10ms:16;100ms:236)
Counters  256

Internal memory bits stored on power down

256

Time interrupts 2 with1ms resolution
Edge interrupts 4 up and / or 4 down
Analog adjustment 2 with 8 bit resolution

Boolean execution speed

0.08µs per instruction

Real Time Clock Built-in
Communications Built-in  
Ports 2 RS-485 ports, within1standard PPI port
PPI Baud Rates 9.6,19.2 and 187.5 kbaud
Freeport Baud Rates 1.2kbaud to 115.2kbps
Max. cable length per segment

With isolated repeater:1000 m up to 187.5kbaud,

 1200 m up to 38.4kbaud Without isolated repeater: 50 m

Max. number of stations 32 per segment, 126 per network
Max. number of masters 32
Peer to peer(PPI Master Mode) No
Power  
Input voltage 85 to 264 V AC(47 to 63Hz)
Input current 60/30mA while CPU only at 120/240V AC
200/100Ma while Max. load at 120/240V AC
Inrush current 20A at 264 V AC
Isolation(field to logic) 1500 V AC
Hold up time(loss of power) 1s at 120/240 V AC
Sensor voltage 20.4 to 28.8 V DC
Current limit 1.5A peak, thermal limit non-destructive
Ripple noise (sensor to logic) Less than 1V peak-to-peak
Isolation (sensor to logic) Not isolated
CPU Digital Input Specifications
Built-in digital input 14 inputs
Input type PNP/NPN
Rated voltage 24 V DC at 4mA
Max. continuous  permissible voltage 30V DC
Surge voltage 35 V DC,0.5s
Logic “1”  voltage range 15 to 30

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now