FD3.8-2.5kw Variable pitch wind turbine IEC61400-2 home use mini Wind power generator
Advantages :
- Blades rotor: Blades rotor efficiency can reach 0.42. Noise level is less than 65db, and balance adjustment has been carried out strictly before leaving factory.
- Generator: Blades rotor drives directly. Lower rotation speed, PMG synchronous generator, over load capacity is 150%.
- Pitch controlled wind turbine: Adopt stable pitch controlled system, can be used in variable environments
- Low failure rate
- Speed regulates Performance: The precision of pitch controlled system is 10 r/min, and never over speed at gale. Low Start up Wind Speed: According to different wind conditions, adjust the blade initial angle to make wind turbine start up at low wind speed.
- The start-up wind speed is ≤3m/s.
- Manual brake: Reliable braking system, easy to operate, can stop wind turbine at any time.
- Automatically undo cable: slip rings undo the cable automatically. Ensure the cable has not twist. Double carbon brushes structure make sure power transfer without failure.
- Well-adapted Wind turbine: The operation wind speed is 3-30m/s.
Specification :
Blades rotor Diameter (m) |
3.8 |
Material and number of the blades |
FRB 3 PCS |
Rated power / max power (w) |
2.5k/3.5k |
Rated wind speed (m/s) |
10 |
Startup wind speed (m/s) |
3 |
Working wind speed (m/s) |
3-25 |
Start up torque(N.m) |
1.4 |
Survived wind speed (m/s) |
40 |
Rated rotation speed (r/min) |
380 |
Working Voltage (V) |
DC24--300v |
Generator style |
3 phase ,AC PMG |
Speed regulation method |
centrifugal pitch control, yaw |
Stop method |
Brake by hand drag + electromagnet brake |
Working system |
Off-grid working system/ |
Guy wire tower Height |
8m,9m,10m,12m,15m |
Tilting up Tower height |
8m,9m,10m,12m,15m |
wind turbine output power curve:
Other variable pitch wind turbine models:
Pitch Control Wind Turbine Technical Parameters | |||||||
Item | FD3.8-2.5kw | FD4-3kw | FD5.4-5kw | FD10-10kw | FD12-20kw | FD14-30kw | FD23-50kw |
Rotor diameter(m) | 3.8 | 4 | 5.4 | 10 | 12 | 14 | 23 |
Blade material | Reinforced FPR | Reinforced FPR | Reinforced FPR | ||||
Blade quantity | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Rated wind speed (m/s) | 9 | 10 | 10 | 10 | 10 | 9 | 9 |
Start-up wind speed(m/s) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Working wind speed(m/s) | 3.0-25 | 3.0-35 | 3.0-35 | 3.0-35 | 3.0-35 | 3.0-35 | 3.0-35 |
Security wind speed(m/s) | 40 | 40 | 45 | 45 | 50 | 50 | 50 |
Starting torque(n/m) | 1.4 | 2.5 | 4.5 | 7.5 | 14 | 20 | 110 |
Speed adjusting mode | Centrifugal Pitch Control | Active Pitch Control, Active Yawing | |||||
Stop method | Electromagnetic + Manual brake | Feathering,Yawing,Electromagnetic | |||||
Generator type | Permanent Magnet Three phase AC generator | ||||||
Rated power | 2KW | 3KW | 5KW | 10KW | 20KW | 30KW | 50KW |
Maximum power | 3KW | 4KW | 6KW | 12KW | 25KW | 35KW | 60KW |
Rated RPM(r/min) | 380 | 300 | 240 | 180 | 150 | 140 | 60 |
Working voltage | DC24V-500V | DC48V-500V | DC48V-500V | DC120V-500V | DC240V-500V | DC500V | DC700V |
Wind turbine weight(kg) | 130 | 160 | 260 | 1000 | 2500 | 2800 | 6580 |
Wind turbine main body assembly : 400w camping wind generator
Perfect design :
Working system:
The DC Max voltage |
600Vdc |
The DC range |
30V~540Vdc |
The rating max DC input current |
20Adc |
The rating grid voltage |
230Vac or 240Vac |
The grid voltage range |
180~270Vac (adjustable) |
Operation phase |
single |
Rating grid output current |
13.0Aac/12.5Aac |
Rating output power |
3.0KW |
Grid current THD |
Total THd<4%, |
The DC injection current |
<20mA |
Output power factor |
>0.99 |
Grid frequency range |
47.0~52.0Hz /57.0~62.0Hz(adjustable) |
Max efficiency |
>96.5% |
Design lifetime |
>20 years |
Operation environment temperature |
25~60 |
Wind (solar hybrid) on grid system
Wind (solar hybrid) off grid working system
3kw PWM 380v on grid controller normal spec:
Power of the equipped wind turbine (W) |
3K |
Operating mode |
Continuous |
Function |
Commutation, control |
Operating environment |
Temperature -30~40℃, humidity≤80% |
PWM unloading voltage (DCV) |
≥350V |
Brake voltage (DCV) |
380±2V |
Brake delay time (min) |
10-20 minutes |
Self-provided connecting wire of the PWM dump load(mm²) |
>4mm² |
PWM unloading fuse (A) |
16A |
DC output fuse (A) |
16A |
3kw 48v PWM Charge controller with normal spec:
Wind turbine power (W) |
3KW |
Solar panel power (W) |
1000W |
Battery |
48 |
Operating mode |
Continuous |
Function |
Charge, control |
Operating environment |
Temperature -30-40℃, humidity≤80% |
PWM dump load voltage (v) |
>58V |
Three-phase dump load voltage of the wind turbine (v) |
60V±1 |
Recovery charging voltage of the wind turbine (v) |
56V±1 |
Power shortage of the battery (V) |
40V±1 |
Solar stop charge voltage(V) |
60V±1 |
Recovery charging voltage of the solar(v) |
<58V |
Self-provided connecting wire of the battery (mm²) |
>16mm² |
Self-provided connecting wire of the PWM dump load (mm²) |
>12mm² |
PWM fuse(A) |
63A |
Home and Abroad Applications:
System Relaed Products :
Packing and Shipping :
Item | Products description | Q'ty | Packing size(m) | G.W(kg) | Cubage(m3) | Q'ty | Remark |
1 |
3kw variable pitch generator /nacelle,hub assembly, nose cone,manual brake |
1 | 1.36*0.78*0.74 | 375 | 0.78 | 1 | plywood case |
2 | Blades and tail | 1 | 1.93*0.3*0.25 | 44 | 0.14 | 1 | |
TTL: | 419 | 0.92 | 2 |
We manufacture 300w-30kw fixed pitch wind turbine;
2kw, 3kw, 5kw, 10kw, 20kw, 30kw, 50kw, 60kw pitch controlled wind turbine;
1kw, 2kw, 3kw, 5kw Vertical axis wind turbine;
On grid system/off grid system, wind solar hybrid system; Water heating system;
For more details, pls contact with us via e-mail.
Thanks!
Our Certificates and wind turbine test report :
Our Factory :
1. Wind tubine model selection
Pls check your local place average wind speed,then we will provide recommend model for you.
Low average wind speed place can select larger bldes rotor, higher tower, higher voltage wind turbine;
Rich wind place can select normal blades rotor diameter. Speed limited system.
2. Working system
If you local place has grid power, you can select:
off grid system +grid power hybrid system; Wind solar off grid sysem + grid power hybid system;
On grid system;
If there is no grid power, you can select wnd tubine off grid system + backup power hybid ystem;
Wind solar off grid system + backup power hybrid system.
3. Tower selection:
The blades rotor bottom tip should be higher than max surrounding barrier.
For more details, pls contact with us.
Contact me :
24 hours contact with us via: