Specifications
Aluminum Stranded Wire and Aluminum Conductor Steel-reinforcedsells well in Europe, USA,Iran,India,Vietnam etc
Aluminum Stranded Wire and Aluminum Conductor Steel-reinforced
Application
The Aluminum Stranded Wire and Aluminum Conductor Steel-reinforced apply for electric transmission line overhead.
Specification and Produce range
No. | Specification | Name | Cross-sectional area | Standard |
1 | LJ | Aluminum stranded wire | 16~800 | GB/T1179-1999 |
2 | LGJ | Aluminum conductor steel-reinforced | 10/2~800/100 | |
3 | LGJF | Anticorrosive aluminum conductor steel-reinforced | 10/2~800/100 | |
4 | JL | Aluminum stranded wire | 10~800 | GB/T 1179-1999 |
5 | JLHA2,JLHA1 | Aluminum alloy stranded wire | 16~800 | |
6 | JL/G1A,JL/G1B,JL/G2A,JL/G2B,JL/G3A | Aluminum conductor steel-reinforced | 16~800 | |
7 | JL/G1AF,JL/G2AF,JL/G3AF | Anticorrosive aluminum conductor steel-reinforced | 16~800 | |
8 | JLHA2/G1A,JLHA2/G1B,JLHA2/G3A | Aluminum alloy conductor steel-reinforced | 16~800 | |
9 | JLHA1/G1A,JLHA1/G1B,JLHA1/G3A | Aluminum alloy conductor steel-reinforced | 16~800 | |
10 | JL/LHA2,JL/LHA1 | Aluminum conductor aluminum alloy reinforced | 16~800 | |
11 | JL/LB1A | Aluminum conductor aluminum coated steel-reinforced | 16~800 | |
12 | JLHA2/LB1A,JLHA1/LB1A | Aluminum alloy conductor aluminum coated steel-reinforced | 16~800 | |
13 | JG1A,JG1B,JG2A,JG3A | Steel stranded wire | 4~63 | |
14 | JLB1A,JLB1B,JLB2 | Aluminum coated steel stranded wire | 4~200 |
Technical Data
Aluminum Stranded Wire
Nominal cross-sectional area mm2 | Construction No. /Diameter mm | Calculated cross-section mm2 | Overall diameter mm | D.C. resistance of conductor Ω/km | Calculated tensile force N |
Appro. Weight kg/km | Delivery length m |
16 | 7/1.70 | 15.89 | 5.1 | 1.802 | 2840 | 43 | 4000 |
25 | 7/2.15 | 25.41 | 6.4 | 1.127 | 4355 | 69 | 3000 |
35 | 7/2.50 | 34.36 | 7.5 | 0.8332 | 5760 | 94 | 2000 |
50 | 7/3.00 | 49.48 | 9.0 | 0.5786 | 7930 | 135 | 1500 |
... | |||||||
400 | 37/3.70 | 397.83 | 25.9 | 0.07247 | 61150 | 1097 | 1000 |
500 | 37/4.16 | 502.90 | 29.1 | 0.05733 | 76370 | 1387 | 1000 |
630 | 61/3.63 | 631.30 | 32.6 | 0.04577 | 91940 | 1744 | 800 |
800 | 61/4.10 | 805.36 | 36.9 | 0.03588 | 115900 | 2225 | 800 |
GB/T1179-1999
Aluminum Stranded Wire
Specification | Cross-sectional mm2 | No. of single wire N | Diameter | Weight kg/km | Rated tensile force kN | D.C. resistance of conductor at 20℃ Ω/km | |
Single wire mm | Stranded conductor mm | ||||||
10 | 10 | 7 | 1.35 | 4.05 | 27 | 1.95 | 2.8633 |
16 | 16 | 7 | 1.71 | 5.12 | 43 | 3.04 | 1.7896 |
25 | 25 | 7 | 2.13 | 6.40 | 68 | 4.50 | 1.1453 |
40 | 40 | 7 | 2.70 | 8.09 | 109 | 6.80 | 0.7158 |
63 | 63 | 7 | 3.39 | 10.2 | 172 | 10.39 | 0.4545 |
100 | 100 | 19 | 2.59 | 12.9 | 274 | 17.00 | 0.2877 |
125 | 125 | 19 | 2.89 | 14.5 | 343 | 21.25 | 0.2302 |
160 | 160 | 19 | 3.27 | 16.4 | 439 | 26.40 | 0.1798 |
... | |||||||
1120 | 1120 | 91 | 3.96 | 43.5 | 3093 | 179.20 | 0.0258 |
1250 | 1250 | 91 | 4.18 | 46.0 | 3452 | 200.00 | 0.0231 |
1400 | 1400 | 91 | 4.43 | 48.7 | 3866 | 224.00 | 0.0207 |
1500 | 1500 | 91 | 4.58 | 50.4 | 4143 | 240.00 | 0.0193 |
GB/T1179-1999
Aluminum Conductor steel-reinforced
Speci- fica- tion | % Steel rate | Area | No. of wire | Diameter of single wire | Diameter | Weight kg/km | Rated tensile force | 20℃ D.C. resistance of conductor at 20℃ Ω/km | ||||||||||||
Al. | St. | Total | Al. | St. | Al. | St. | Steel core | Conductor | JL/G1A | JL/G1B | JL/G2A | JL/G2B | JL/G3A | |||||||
mm2 | mm | mm | KN | |||||||||||||||||
16 | 17 | 16 | 2.67 | 18.7 | 6 | 1 | 1.84 | 1.84 | 1.84 | 5.53 | 64 | 6.08 | 5.89 | 6.45 | 6.27 | 6.83 | 1.7934 | |||
25 | 17 | 25 | 4.17 | 29.2 | 6 | 1 | 2.30 | 2.30 | 2.30 | 6.91 | 100 | 9.13 | 8.83 | 9.71 | 9.42 | 10.25 | 1.1478 | |||
40 | 17 | 40 | 6.67 | 46.7 | 6 | 1 | 2.91 | 2.91 | 2.91 | 8.74 | 161 | 14.40 | 13.93 | 15.33 | 14.87 | 16.20 | 0.7174 | |||
63 | 17 | 63 | 10.5 | 73.5 | 6 | 1 | 3.66 | 3.66 | 3.66 | 11.0 | 254 | 21.63 | 20.58 | 22.37 | 21.63 | 24.15 | 0.4555 | |||
... | ||||||||||||||||||||
1000 | 4 | 1000 | 43.2 | 1043 | 72 | 7 | 4.21 | 2.80 | 8.41 | 42.1 | 3100 | 209.26 | 206.23 | 215.31 | 212.28 | 220.93 | 0.0289 | |||
1120 | 4 | 1120 | 47.3 | 1167 | 72 | 19 | 4.45 | 1.78 | 8.90 | 44.5 | 3464 | 234.53 | 231.22 | 241.15 | 237.84 | 247.77 | 0.0258 | |||
1120 | 8 | 1120 | 91.2 | 1211 | 84 | 19 | 4.12 | 2.47 | 12.4 | 45.3 | 3811 | 283.17 | 276.78 | 295.94 | 289.55 | 307.79 | 0.0258 | |||
1250 | 4 | 1250 | 52.8 | 1303 | 72 | 19 | 4.70 | 1.88 | 9.40 | 47.0 | 3867 | 261.75 | 258.06 | 269.14 | 265.44 | 276.53 | 0.0231 | |||
1250 | 8 | 1250 | 102 | 1352 | 84 | 19 | 4.35 | 2.61 | 13.1 | 47.9 | 4253 | 316.04 | 308.91 | 330.29 | 232.16 | 343.52 | 0.0232 | |||
The data in above table also fit for anti-corrosive Aluminum conductor steel reinforced with the specification JFL/G1A,JFL/G2A,JFL/G3A.
Aluminum conductor steel-reinforced and Anti-corrosive Aluminum conductor steel-reinforced
Nominal cross-sectional Al./St. mm2 | Construction No./Diameter mm | Calculated cross-section mm2 | Overall diameter mm | D.C. resistance of conductor
Ω/km | Calculated tensile force N | Appro. Weight kg/km | Delivery length m | |||
Al. | St. | Al. | St. | Total | ||||||
10/2 | 6/1.50 | 1/1.50 | 10.60 | 1.77 | 12.37 | 4.5 | 2.706 | 4.12 | 42 | 3000 |
16/3 | 6/1.85 | 1/1.85 | 16.13 | 2.69 | 18.82 | 5.5 | 1.779 | 6.13 | 65 | 3000 |
25/4 | 6/2.32 | 1/2.32 | 25.36 | 4.23 | 29.59 | 6.9 | 1.131 | 9.29 | 102 | 3000 |
35/6 | 6/2.72 | 1/2.72 | 34.86 | 5.81 | 40.67 | 8.1 | 0.8230 | 12.63 | 141 | 3000 |
50/8 | 6/3.20 | 1/3.20 | 48.25 | 8.04 | 56.29 | 9.6 | 0.5946 | 16.87 | 195 | 2000 |
... | .... | |||||||||
630/45 | 45/4.20 | 7/2.80 | 623.45 | 43.10 | 666.55 | 33.6 | 0.04633 | 148.70 | 2060 | 1200 |
630/55 | 48/4.12 | 7/3.20 | 639.92 | 56.30 | 696.22 | 34.3 | 0.04514 | 164.40 | 2209 | 1200 |
630/80 | 54/3.87 | 19/2.32 | 635.19 | 80.32 | 715.51 | 34.8 | 0.04551 | 192.90 | 2388 | 1200 |
800/55 | 45/4.80 | 7/3.20 | 814.30 | 56.30 | 870.60 | 38.4 | 0.03547 | 191.50 | 2690 | 1000 |
800/70 | 48/4.63 | 7/3.60 | 808.15 | 71.25 | 879.40 | 38.5 | 0.03574 | 207.00 | 2791 | 1000 |
800/100 | 54/4.33 | 19/2.60 | 795.17 | 100.88 | 896.05 | 38.9 | 0.03635 | 241.10 | 2991 | 1000 |
If you have any questions, pls don't hesitate to contact me! |
Morgan |
Hebei New Baofeng Wire & Cable Co.,Ltd |
ADD: Jinghe Industrial Zone, Hejian City, Hebei Province China |
Web: www.nbfcable.com |Email: sales4 at nbfcable.com |
Tel: 86-531-58617867 |Mob:86-15098767265 |
Fax: 86-531-88015590 |Skype: morganren-china|QQ:1733109349 |
Website: www.ur-brand.net www.ur-brand.net www.ur-brand.net http://nbfcable.en.china.cn/ http://www.nbfcable.com/english/about.asp |