Product Details

Gas Chromatograph for Boiling Range Distribution DGA-2014B

Product Features

Gas Chromatograph for Boiling Range Distribution DGA-2014B

1.Applicable boiling range: petroleum products or distillates of 55~550℃ boiling range distribution such as fuel, kerosene, diesel, lubricants, wax oil etc. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity. It complies to SH/T 0558-2002 and ASTM D2887standard.
2.Applicable boiling range: crude oil of initial boiling point~538℃ boiling range distribution. Get distribution proportion of
fuel, diesel, kerosene, heavy oil. Since the heavy components above 538℃ can not show peak, it adopts incremental internal standard method and complies to ASTM D5307 standard.
3.Applicable boiling range: petroleum products or distillates of 55~680℃ boiling range distribution. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization method to fix quantity.
1. Adopts American Agilent 5890 gas chromatographic core tech; green backlight LCD screen; easy operation.
2. Temperature control upper limit max use temperature of 450℃for every instrument heating area.
3. Dual channel single column compensation; base line drift when program heat to operate FID test; ensure base line straight and chromatography peak shape perfect.
4. Adopts imported heat-resistant large aperture metal capillary column to separate; mas analysis use temperature of 450℃.
5. Can display and print C5-C44 n-alkanes calibration sample boiling point-time calibration curve.
6. Can provide oil sample boiling point-yield boiling range curve.
7. Can provide detailed boiling range report regarding 1% yield interval; also can provide it regarding 5℃, 10℃, 20℃, 30℃, 50℃,100℃ boiling range.
8. Can be equipped with AS-2902 highly efficient auto liquid sample injector; auto injection analysis with unattended operation achieved; analysis efficiency improved and labor intensity reduced.

Temperature control index
Oven/ Sample injector/ detector: above room temperature 5℃~450℃; precision ±0.1℃

Column oven parameters
Temperature control range: above room temperature 5℃~450℃; precision ±0.1℃
Program heating stages: 3 stages
Program heating speed: 0.1℃~50℃, increment 0.1℃
Program heating keeping time: 0~655 min (increment 1 min)
Big oven volume; back pullout design; program quick cooking after heating. Cooling speed: only 7min from 350℃ down to 60℃.

Injection method
Capillary split/unsplit stream injection: flash distillation injection
Packed column head injection: flash distillation injection
Can be equipped with unattended operation auto injector.

Hydrogen flame ionization detector (FID)
Easy disassembly and installation; convenient for cleaning and displacing nozzle; easy operation; can input signal to logarithmic
amplification to reduce interference; high sensitivity, good linearity and wide range.
Limit of detection (LOD): Mt ≤ 5×10-12g/s (n-Hexadecath)
Baseline noise: ≤ 6×10-12A/H
Linearity range: ≥ 105
Stability time: < 0.5h

Chromatographic working station
24 bits high precision digital-to-analogue conversion (DAC)
Dual channel synchronous or asynchronous work
USB port; can be connected to external power supply; with serial port
Input voltage range: -1V~1V
Integral sensitivity: 0.05uV•s
Min solution: 1uV
Dynamic range (DR): 107
Sample frequency: Max 60 times/sec; adjustable program variables

1.1.Fully Automatic Karl Fischer Water Content Tester TP-2100
2.Digital Karl Fischer Water Content Tester TP-6A
3.Kinematic Viscosity Tester VST-2000
4.Kinematic Viscosity Tester TPV-8
5.Kinematic Viscosity Tester VST-3000
6.Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
7.Fully Automatic Surface/Interface Tension Tester IT-800

8.Automatic Surface/Interface Tension Tester (Platinum Plate Method) IT-800P
9.Fully Automatic Open Cup Flash Point Tester TPO-3000
10.Fully Automatic Closed Cup Flash Point Tester TPC-3000
11.Digital Open Cup Flash Point Tester TPO-100
12.Digital Closed Cup Flash Point Tester TPC-100
13.Cloud Point & Pour Point Tester PT-2000

MOQ
1 Set
Trade Terms
EXW, FOB, CIF, CFR
Payment Terms
T/T, L/C
Port of Loading
Any Port of China
Packing Method
Internaional Standard Wooden Case
Transportation Method
By Sea, By Land, By Air, By Express
Supply Capability
100 Sets/Month

* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 1 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.

Chongqing TOP Oil Purifier Co., Ltd

Located at Chongqing city--a southwest electromechanical manufacturing center as well as national municipality, Chongqing TOP is a professional leading manufacturer and supplier of oil purifiers and various related testers. Our company consists of departments respectively for technological development, machinery manufacture, instrument manufacture and quality control etc.

Welcome to visit our website, welcome your inquiry.

Ray Tuo | Sales Manager
CHONGQING TOP OIL PURIFIER CO.,LTD
Manufacture oil purifiers and supply test equipment.
Add: No. 1, Jianlong N. Rd., Jiulongpo District, Chongqing, China
E: sales7@topoilpurifier.com
Cell: 0086-13340266216 (Whatsapp/Wechat) | Skype: topoilpurifier
Tel: 0086-23-88901306 | Fax: 0086-23-88901306
;

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now