Products Description
Features | ||||||||
◆ Full digital beam-former, Digital dynamic focusing, Digital variable aperture and dynamic apodizer, 32 A/D sampling channels are included for receiving and launching channels. ◆ High-density probe and wider frequency band optimize image quality of far and near field. ◆ High resolution LCD monitor, flicker-free, which can reduce the visual fatigue of the operator. ◆ The ergonomic design silicon keyboard with backlit, which is more suitable for the user. ◆ Regulated voltage power is adopted, strong suitability. | ||||||||
Standard Configuration | SV8 Main Unit + Micro Convex / Linear Probe + Battery+DICOM 3.0 | ||||||
Display | 15“High Resolution LCD Display | ||||||
Connector | 1 Probe Connector, 3 probes connector extension optional | ||||||
Weight | 6.0kg | ||||||
Optional Configuration | Mobile Trolley or Carrying Bag | ||||||
Languages | English, Italian, Portuguese, Russian, Spanish, Deutsch, French | ||||||
Display Mode | B, 2B, 4B, M, B+M, CFM, PDI, B+PW, B+CFM+PW, B+PDI+PW | ||||||
Type of Focusing | Dynamic focusing, acoustic lens focusing, launching multipoint focusing | ||||||
Pre-processing | low noise preamplifier, TGC, filtering, frame average, line average | ||||||
Character | Date, time, owner name, animal name, device name, user name etc, user-defined annotation table, arrowhead and body marks Measurement Software:Software packages of animal abdomen, Obstetrics, Urology, Cardiology, and small parts; directly form diagnostic report based on measurement results. | ||||||
Body Mark | 37 body marks with probe location | ||||||
Digital Scan Converter | 628 440 24 bits | ||||||
Size | 78 mm(H)×360 mm(W)× 370 mm(L) |
Recommend Products
Company Profile
FAQ
◆Do not use the equipment near devices generating high frequency (such as medical telemeters and cordless telephones). If so, the equipment may malfunction or adversely affect such devices. ◆This ultrasound imaging system, the same as other ultrasound diagnostic devices, is advised to apply within the short period of time under the condition of obtaining enough necessary clinical information. And the power setting is advised to reasonably low enough, as long as the images can be obtained correctly. The heat of probe is no more than 43 C, by enlarging the neighbor interval time, and reducing unit ejecting times. ◆Finish the diagnosis at the shortest time and at the lowest power.
◆Keep the probe in frozen status when no scanning. ●Do not aim at the animal unless it is necessary. Avoid fixing the probe to the same region of animal for a long period of time. ●Warming: The Ultrasound Imaging System is not suitable for therapy! | ||||||||