Product Details

GI-5000-01 Gas Chromatograph

Brand Name TYYQ
Place of Origin Shaanxi, China
Model Number GI-5000-01(S)

Product Features

Instrument introduction:

A clear display: Large-screen display makes the display clearer and easier to operate. It can display the path rise curve and the base flow level (the acquisition board needs to be configured), and simultaneously display the temperature setting value and actual value of the oven, the injector, the detector, etc. in one screen, which can provide more colorful Instrument information

 

High-performance microcomputer temperature control system: It adopts international advanced manufacturing technology, high temperature control precision (better than ±0.05°C), high reliability and strong anti-interference ability; 6 independent temperature control zones, the highest control temperature 400 ° C; limit temperature setting and over temperature protection to ensure the safe operation of the instrument. All Chinese keyboards set various control and usage parameters (including detector operating parameters), which are logical and easy to operate; the instrument has self-diagnosis, power-off protection, detector setting, range, polarity and current setting and display, etc. Function, can accurately display the temperature control set value, actual value, retention and analysis time, etc.

 

High-performance large-capacity oven: Large-capacity oven can accommodate both capillary column and double-filled column; the oven has rapid heating and rapid cooling, that is, automatic rear door opening mechanism (from 300 ° C to 50 ° C within 10 min, can automatically change according to temperature changes) Adjust the door opening angle), and can realize the quasi-room temperature control. The oven has a 10th order 11 platform program temperature (requires back control software support)

 

High-precision dual-stabilized gas path: The carrier gas flow path adopts the double-stabilized design of the pressure-regulating valve and the steady-state valve; the air and hydrogen flow path adopts the steady-state regulation mode of the pressure-regulating valve plus the needle-shaped valve, the steady flow valve and the needle valve are all digital. Scale knob with high precision, repeatability, high reliability and convenient flow adjustment

 

Flexible injection system to meet various analytical requirements: The instrument can be installed with up to three injectors at the same time. According to the analysis requirements, the best injector combination can be selected, and each unit can be independently temperature controlled, and the sampler can be disassembled and assembled. simple. Single packed column / double packed column injector (PIP): can be used to fill the column head injection method, suitable for a variety of columns; add a six-way valve for gas injection analysis; use the connector in the packed column sampler, The 0.53 wide-bore capillary column analysis can be easily performed. Single Capillary Column / Double Capillary Column Sampler (SPL): Dedicated capillary column injector with diaphragm purge and back pressure valve split adjustment for a wide range of capillary columns

 

High Sensitivity, High Stability Detector: The instrument can be installed with up to three detectors simultaneously, such as FID, TCD, ECD detectors, etc. Depending on the analysis application, different combinations can be used to facilitate the series and parallel operation of the detector. The new FID has a lower detection limit for easy disassembly and cleaning of the spout and ion collection components. The precisely fixed emitter mounting structure ensures a consistently high performance of each instrument. The unique air insulation structure gives TCD a higher stability. High-sensitivity HTCD uses high-resistance tantalum tungsten wire with sensitivity up to 10000mV. mL/mg. Modulated pulsed ECD constant current source, sensitivity and current selection

 

New built-in acquisition system: Advanced built-in acquisition device that can collect instrument control status and chromatographic output signals, and connect to an external computer with a communication line for real-time control and data processing. (Need to configure anti-control software and acquisition board) Real-time control includes various temperature control, detector selection and setting, program temperature control and temperature-programming curve tracking, flow value display and other functions. Data processing includes dual channel (expandable to multi-channel) high-speed chromatographic data acquisition, automatic or manual setting of integration parameters, up to five quantitative methods, baseline subtraction, report compilation, etc.

 

Digital carrier gas flow monitoring system: The GI-5000-01 pneumatic system can be equipped with the latest digital flow monitoring unit. The screen displays the carrier gas flow and capillary flow value, and can display up to 4 groups of flow, and the flow parameters can be automatically Storage, easy to analyze the recording and calling of conditions. Convenient for split flow adjustment and split ratio calculation, no need to use soap membrane flowmeter

 

Technical Parameters

temperature control:

Temperature control range: 7 ° C ~ 400 ° C at room temperature (increment 1 ° C)

High Sensitivity Thermal Pool Detector (HTCD)

Sensitivity: ≥10000mV. mL/mg sample C16

Temperature control object: oven, front and rear detector, front and rear injector, auxiliary, total 6 channels

Electronic capture detector (ECD)

Detection limit: ≤1×10-13g/s sample γ-666

Cheng Sheng order: seventh order

Linear range: ≥103

Cheng Sheng rate: 0.1 ° C ~ 40 ° C / min (increment 0.1 ° C)

Maximum operating temperature: 350 ° C

Constant temperature time: 0~655min (increment 1min)

Flame Photometric Detector (FPD)

Detection limit: ≤ 2 × 10-11g / s (P) Sample: methyl parathion ≤ 1 × 10-10g / s (S) Sample: methyl parathion

 

Hydrogen Flame Ionization Detector (FID):

Sensitivity: M≤8×1

0-12g/s sample C16

Nitrogen and Phosphorus Detector (NPD)

Detection limit: ≤ 5 × 10-12g / s (N) Sample: azobenzene ≤ 5 × 10-13g / s (P) Sample: malathion

Best test result: M≤3×10-12g/s sample C16

Photoion ion detector (PID)

Detection limit: ≤1ppb Sample: benzene

Noise: ≤5×10-14A

Drift: ≤6×10-13A/h

Linear range: ≥ 106

Thermal Pool Detector (TCD):

Sensitivity: ≥5000mV. mL/mg sample C16

Noise: ≤20μV

Drift: ≤30μV/h

Linear range: ≥ 104

Host: GI-5000-01 Gas Chromatograph Host Large-screen Chinese display, high-performance oven, double stable gas path

 

Injector: PIP packed column injector for on-column injection, suitable for packed columns of various sizes

SPL capillary column injector with diaphragm purge and backpressure valve split adjustment, makeup adjustment

Detector: FID Hydrogen Flame Ionization Detector With modular structure, it is easy to disassemble and clean.

TCD Thermal Conductivity Detector High quality tantalum tungsten wire, constant current source control, double packed column balance mode

HTCD High Sensitivity Thermal Conductivity Detector High quality tantalum tungsten wire, constant current source control, double packed column balance mode

ECD electron capture detector with Ni63 source, extremely sensitive to halogen compounds

FPD flame photometric detector Double flame-optical fiber structure with high response to trace phosphorus and sulfur organics

NPD Nitrogen Phosphorus Detector Highly stable bead, highly sensitive to nitrogen and phosphorus organics

PID photoelectric ionization detector Non-destructive detection, using photons to achieve sample ionization, no radioactive source

Optional accessories: Anti-control software and acquisition board Control the temperature, process and data processing of the instrument through the computer

FPD special valve assembly Eliminate changes to the air circuit when replacing the detector

Dual PIP to SPL kit Double packed column to change capillary gas path components

Digital flow display component displays flow values through the host screen

GI-5000-01 Gas Chromatograph

Company Information

GI-5000-01 Gas Chromatograph

 

Dear customer :

We,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history.

Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing,bioscience,medical apparatus and instruments,internet technology and some frontier science.

   
GI-5000-01 Gas Chromatograph GI-5000-01 Gas Chromatograph GI-5000-01 Gas Chromatograph
   
GI-5000-01 Gas ChromatographGI-5000-01 Gas ChromatographGI-5000-01 Gas Chromatograph
   

Through a long-time development,we own a national resources system of various professional talents,abundant supply for various components & parts and special materials, full producing &processing equipments,strong Technological standardization and a complete quality assurance system.

If you need OEM or ODM in manufacturing ,scientific research,market development and or you want to build your own brand in your country,it’s our honor to cooperate with you.In this way,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba.

We firmly believe that science and technology is no boundaries.

Our mission is to make every effort to contribute to all humanity.

 

Your earlier friendly enquire from us would be highly appreciated.Thanks in advance!

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now