Nitrogen charging cart
Nitrogen filling vehicle
CDZ nitrogen charging vehicle
Model description
CDZ-35-Y1
CDZ: Nitrogen filling cart
35:Maximum charging pressure. 25,35,42Mpa
Y1: Charging cylinder reversing mode. Y1:hydraulic controlled pilot-operated type
Nitrogen charging cart is also called nitrogen-filling tool, nitrogen booster
CDZ nitrogen charging vehicle is a special equipment used to fill nitrogen into hydraulic- bladder/capsule accumulators, piston accumulators, hydraulic diaphragm accumulators and other high-pressure vessels and increase nitrogen pressure.
Usually, when the nitrogen is filled to the accumulator directly from the nitrogen bottles, the maximum nitrogen filling pressure is 13.5Mpa. If the pre-charged nitrogen pressure required in the accumulator exceeds 13.5Mpa, this nitrogen filling cart can be used to realize this. The highest pressure can reach 42Mpa.
Working principle
This nitrogen charging cart consists of three parts: hydraulic system, gas circuit and electrical circuit. The pilot selector valve of the hydraulic system controls the two-way supercharger to reciprocate continuously. One gas cavity sucks nitrogen from the nitrogen bottles, and the other gas cavity presses the sucked nitrogen into the accumulator or high-pressure container through the valve device. When the nitrogen pressure in the accumulator reaches the pre-set value, the electric contact pressure gauge sends a signal to stop the hydraulic system.
Technical specifications
Model | Nitrogen input pressure(Mpa) | Maximum output pressure(Mpa) | Oil pump | Supercharger | Weight (kg) | ||
Pressure(Mpa) | Flow(L/min) | supercharge ratio | Boost times (times / min) | ||||
CDZ-25Y1 | 3.0-13.5 | 25 | 7 | 9 | 1:4 | 8 | 338 |
CDZ-35Y1 | 35 | 1:6 | 6 | ||||
CDZ-42Y1 | 42 | 8 | 14-16 | 1:7 | 7.5 |
Precautions for use and order
1.This product is only suitable for nitrogen. The use of oxygen or other flammable and corrosive gases is strictly prohibited.
2.The nitrogen filling pressure has been adjusted well according to the user's requirements when leaving factory. It can be directly used after connecting to the power supply without adjustment again. If you want to change the nitrogen filling pressure, it just need to adjust the electrical contact position of the electric contact pressure gauge.
3.In addition to the full code of the complete model, the actual nitrogen charging pressure should also be indicated when ordering.