Product Description
High accurancy small lab Equipment adjustable micropipette Plus Pipette
Introduction of Single Channel Pipette MicroPette Plus:
Pipette MicroPette Plus uses the air displacement principle, the piston in the piston sleeve moving at a
fixed range (adjustable), to generate negative pressure, suck in quantitative (adjustable) liquid. It has
many advantages, such as convenient use, reliable performance.
How to use Single Channel Pipette MicroPette Plus:
High accurancy small lab Equipment adjustable micropipette Plus Pipette
1. Put the nozzle on the pipetting head, and rotates gently, so as to ensure the sealing is well.
2. Before using, please suck in or discharge the liquid of the pipette for several times, in order to ensure
inside and outside of the chamber pressure are the same.
3. Hold the pipette vertical, set the button to the first stopping point, and put the suction nozzle immersed
into the liquid, under the liquid surface 2-mm, then slowly release the button, waiting for 1-2 seconds,
after that, take it out from the liquid, and do not let it touch anything.
4. Move the suction nozzle to the sample container wall, slowly push the button to the first stopping point,
waiting for 1-2 seconds, then push the button, exhaust all the liquid, the suction nozzle should be
slided out along the vessel wall, then slowly release the button, that is a complete operation process.
Please note:
High accurancy small lab Equipment adjustable micropipette Plus Pipette
1. The pipette belongs to precise measure, do not allow direct contact with the liquid, when not in use should be inserted on the suction nozzle, keep the tube clean.
2. The use of other manufacturers' suction nozzle, will affect the pipette's accuracy.
3. Room working temperature: 20°C ( ±5°C )
4. The pipette button marking should aim at the required capacity scale line.
Characters:
High accurancy small lab Equipment adjustable micropipette Plus Pipette
1. Fully autoclavable
2. Ergonomic design provides excellent operating experience
3. Easy-to-read volume display
4.The pipettes cover the volume range from 0.1μL to 5mL
5. Easy calibration and maintenance
6. Manufactured from innovative materials
7. Each MicroPette Plus supplied with an 8. Individual calibration certificate according to ISO8655
More Details Photos
Specification
Volume Range | Increment | Test Volume(μl) | Accuracy error | Precision error | ||||
% | μl | % | μl | |||||
0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2.00% | 0.05 | ||
1.25 | 3.00% | 0.0375 | 3.00% | 0.0375 | ||||
0.25 | 12.00% | 0.03 | 6.00% | 0.015 | ||||
0.5-10μl | 0.1μl | 10 | 1.00% | 0.1 | 0.80% | 0.08 | ||
5 | 1.50% | 0.075 | 1.50% | 0.075 | ||||
1 | 2.50% | 0.025 | 1.50% | 0.015 | ||||
2-20μl | 0.5μl | 20 | 0.90% | 0.18 | 0.40% | 0.08 | ||
10 | 1.20% | 0.12 | 1.00% | 0.1 | ||||
2 | 3.00% | 0.06 | 2.00% | 0.04 | ||||
5-50μl | 0.5μl | 50 | 0.60% | 0.3 | 0.30% | 0.15 | ||
25 | 0.90% | 0.225 | 0.60% | 0.15 | ||||
5 | 2.00% | 0.1 | 2.00% | 0.1 | ||||
10-100μl | 1μl | 100 | 0.80% | 0.8 | 0.15% | 0.15 | ||
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||||
10 | 3.00% | 0.3 | 1.50% | 0.15 | ||||
20-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 | ||
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||||
20 | 3.00% | 0.6 | 1.00% | 0.2 | ||||
50-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 | ||
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||||
50 | 1.00% | 0.5 | 0.40% | 0.2 | ||||
100-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 | ||
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||||
100 | 2.00% | 2 | 0.70% | 0.7 | ||||
200-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 | ||
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||||
200 | 0.90% | 1.8 | 0.30% | 0.6 | ||||
1000-5000μl | 50μl | 5000 | 0.50% | 25 | 0.15% | 7.5 | ||
2500 | 0.60% | 15 | 0.30% | 7.5 | ||||
1000 | 0.70% | 7 | 0.30% | 3 | ||||
2-10ml | 0.1ml | 10ml | 0.60% | 60 | 0.20% | 20 | ||
5ml | 1.20% | 60 | 0.30% | 15 | ||||
2ml | 3.00% | 60 | 0.60% | 12 |